stoop
Leaderboard
LeaderboardAbout
Building SafetyHousing Conditions

540 EAST 169 STREET

Bronx · ZIP 10456 · BIN 2004223 · Claremont Village-Claremont (East) · On record since Aug 7, 1990 · Built 1965

NeighborhoodⓘClaremont Village-Clar…
Among the most complained-about buildings in Claremont Village-Claremont (East)
More complaints than 91% of residential buildings in Claremont Village-Claremont (East) over the last 10 years. Size-normalized by building volume.
91st pct
Activity TrendsLast 5 years
Complaints have increased in the last 2 years
↑ Up 18% in the last 2 years (40 vs 34 prior 2 yrs)
50250'21'26
Complaint SeverityⓘLast 10 years
More serious complaints than most buildings nearby
162 Priority A and B complaints over 36 years — 5.9 per year on average. Size-normalized by building volume.
5.9/yr83rd pct(med. 0.1/yr)fewermedianmost
Department of Buildings Complaints
Total complaints since 1990
255
4 active
Total Priority Aⓘ
37
Total Priority Bⓘ
125
No Access for Inspection (past 5 yrs)ⓘ
5%
4 complaints
Complaints over time
5 yrsAll time

First filed Aug 7, 1990. Latest: May 21, 2026.

Complaint log
255total
Active onlyAll
DateComplaint typePriorityStatusClosedOutcome
May 21, 2026

Building Shaking/Vibrating/Structural Stability Affected

30

ACLOSEDMay 22, 2026
See something wrong? File a complaint with 311
Top complaint types
5 yrsAll time
A — ImminentB — SeriousC — StandardD — Minor

No violation warranted for complaint at time of inspection

Apr 25, 2026

Egress – Locked/Blocked/Improper/No Secondary Means

37

ACLOSEDApr 27, 2026

No violation warranted for complaint at time of inspection

Apr 22, 2026

Elevator: Single Device on Property/No Alternate Service

6S

CACTIVE——
Apr 13, 2026

7R

7R

ACTIVE——
Apr 11, 2026

Elevator: Multiple Devices on Property

6M

CACTIVE——
Feb 20, 2026

Elevator: Multiple Devices on Property

6M

CACTIVE——
Feb 4, 2026

8P

8P

CLOSEDFeb 4, 2026

Ecb violation served

Dec 23, 2025

Building Shaking/Vibrating/Structural Stability Affected

30

ACLOSEDDec 25, 2025

Complaint assigned to emergency response team

Nov 15, 2025

Suspended (Hanging) Scaffolds – No Permit/License/Dangerous/Accident

1E

ACLOSEDNov 16, 2025

Partial stop work order p

Nov 15, 2025

Sidewalk Shed/Supported Scaffold – Inadequate/Defective/None/No Permit

23

BCLOSEDNov 18, 2025

No violation warranted for complaint at time of inspection

Nov 13, 2025

Building Shaking/Vibrating/Structural Stability Affected

30

ACLOSEDNov 14, 2025

Inspector unable to gain access - 2nd attempt

Oct 25, 2025

Building Shaking/Vibrating/Structural Stability Affected

30

ACLOSEDOct 27, 2025

Ecb violation served

Oct 2, 2025

Elevator: Multiple Devices on Property

6M

CCLOSEDFeb 19, 2026

Ecb violation served

Sep 19, 2025

Building Shaking/Vibrating/Structural Stability Affected

30

ACLOSEDSep 22, 2025

Inspector unable to gain access - 2nd attempt

Sep 8, 2025

Building Shaking/Vibrating/Structural Stability Affected

30

ACLOSEDSep 10, 2025

Inspector unable to gain access - 2nd attempt

Aug 8, 2025

Sidewalk Shed/Supported Scaffold – Inadequate/Defective/None/No Permit

23

BCLOSEDAug 8, 2025

Ecb violation served

Jul 14, 2025

Local Law Audits

6Y

DCLOSEDJul 14, 2025

Buildings violation(s) served

Jul 14, 2025

Local Law Audits

6Y

DCLOSEDJul 14, 2025

Violation served for disobeying vacate order

Mar 31, 2025

Elevator: Multiple Devices on Property

6M

CCLOSEDOct 1, 2025

Ecb violation served

Mar 22, 2025

Building Shaking/Vibrating/Structural Stability Affected

30

ACLOSEDMar 24, 2025

Insufficient information/unable to locate address

Mar 4, 2025

Work Without a Permit – Occupied Multiple Dwelling

7J

BCLOSEDMar 4, 2025

No violation warranted for complaint at time of inspection

Mar 4, 2025

Site Conditions Endangering Workers

91

ACLOSEDMar 4, 2025

No violation warranted for complaint at time of inspection

Feb 16, 2025

Building Shaking/Vibrating/Structural Stability Affected

30

ACLOSEDFeb 18, 2025

Insufficient information/unable to locate address

Jan 30, 2025

Illegal Conversion

45

BCLOSEDApr 2, 2025

No violation warranted for complaint at time of inspection

Dec 15, 2024

Building Shaking/Vibrating/Structural Stability Affected

30

ACLOSEDDec 16, 2024

No violation warranted for complaint at time of inspection

Nov 1, 2024

Elevator: Multiple Devices on Property

6M

CCLOSEDJan 16, 2025

Ecb violation served

Oct 19, 2024

Elevator: Single Device on Property/No Alternate Service

6S

CCLOSEDOct 25, 2024

Ecb violation served

Oct 11, 2024

Elevator: Single Device on Property/No Alternate Service

6S

CCLOSEDOct 18, 2024

Ecb violation served

Oct 1, 2024

Sidewalk Shed/Supported Scaffold – Inadequate/Defective/None/No Permit

23

BCLOSEDOct 2, 2024

Ecb violation served

Jul 14, 2024

Elevator: Multiple Devices on Property

6M

CCLOSEDOct 18, 2024

Please see complaint number

Jul 14, 2024

Sidewalk Shed/Supported Scaffold – Inadequate/Defective/None/No Permit

23

BCLOSEDJul 15, 2024

Ecb violation served

Jul 10, 2024

Elevator: Multiple Devices on Property

6M

CCLOSEDSep 20, 2024

Please see complaint number

Jun 27, 2024

Elevator: Multiple Devices on Property

6M

CCLOSEDJul 11, 2024

Ecb violation served

Jun 26, 2024

Elevator: Multiple Devices on Property

6M

CCLOSEDJul 11, 2024

Please see complaint number

Jun 24, 2024

Elevator: Single Device on Property/No Alternate Service

6S

CCLOSEDJul 11, 2024

Please see complaint number

Jun 13, 2024

Elevator: Multiple Devices on Property

6M

CCLOSEDJul 11, 2024

Please see complaint number

Jun 13, 2024

Elevator: Multiple Devices on Property

6M

CCLOSEDJul 11, 2024

Please see complaint number

Jun 13, 2024

Elevator: Single Device on Property/No Alternate Service

6S

CCLOSEDJul 11, 2024

Please see complaint number

Jun 13, 2024

Elevator: Multiple Devices on Property

6M

CCLOSEDJul 11, 2024

Please see complaint number

Jun 1, 2024

Elevator: Multiple Devices on Property

6M

CCLOSEDJul 11, 2024

Please see complaint number

May 30, 2024

Elevator: Multiple Devices on Property

6M

CCLOSEDJul 11, 2024

Please see complaint number

May 27, 2024

Elevator: Multiple Devices on Property

6M

CCLOSEDJul 11, 2024

Please see complaint number

May 14, 2024

Building Shaking/Vibrating/Structural Stability Affected

30

ACLOSEDMay 14, 2024

Please see complaint number

May 1, 2024

Building Shaking/Vibrating/Structural Stability Affected

30

ACLOSEDMay 2, 2024

Ecb violation served

May 1, 2024

Building Under Structural Monitoring

2F

DCLOSEDMay 2, 2024N1
May 1, 2024

Building Shaking/Vibrating/Structural Stability Affected

30

ACLOSEDMay 1, 2024

Ecb violation served

Apr 16, 2024

Elevator: Multiple Devices on Property

6M

CCLOSEDMay 30, 2024

Ecb violation served

Mar 23, 2024

Building Shaking/Vibrating/Structural Stability Affected

30

ACLOSEDMar 25, 2024

Please see complaint number

Mar 21, 2024

Elevator: Multiple Devices on Property

6M

CCLOSEDMar 25, 2024

Ecb violation(s) prepared & attempt to serve will be made

Mar 12, 2024

Building Shaking/Vibrating/Structural Stability Affected

30

ACLOSEDMar 14, 2024

Ecb violation served

Page 1 of 6
Next →