stoop
Map
LeaderboardAbout
Building SafetyHousing Conditions

2440 WALTON AVENUE

Bronx · ZIP 10468 · BIN 2014025 · Fordham Heights · On record since Dec 11, 2010 · Built 1926

NeighborhoodⓘFordham Heights
Among the most complained-about buildings in Fordham Heights
More complaints than 100% of residential buildings in Fordham Heights over the last 10 years. Size-normalized by building volume.
100th pct
Activity TrendsLast 5 years
Complaints have increased in the last 2 years
↑ Up 520% in the last 2 years (31 vs 5 prior 2 yrs)
20100'21'26
Complaint SeverityⓘLast 10 years
Among the highest rates of serious complaints nearby
48 Priority A and B complaints over 15 years — 4.5 per year on average. Size-normalized by building volume.
4.5/yr98th pct(med. 0.2/yr)fewermedianmost
Department of Buildings Complaints
Total complaints since 2010
56
6 active
Total Priority Aⓘ
5
Total Priority Bⓘ
43
4 active
No Access for Inspection (past 5 yrs)ⓘ
27%
9 complaints
Complaints over time
5 yrsAll time

First filed Dec 11, 2010. Latest: Apr 17, 2026.

Top complaint types
5 yrsAll time
A — ImminentB — SeriousC — StandardD — Minor
Complaint log
56total
Active onlyAll
DateComplaint typePriorityStatusClosedOutcome
Apr 17, 2026

Electrical Wiring: Defective/Exposed – In Progress

59

BACTIVE——
See something wrong? File a complaint with 311
Apr 17, 2026

Electrical Wiring: Defective/Exposed – In Progress

59

BACTIVE——
Apr 14, 2026

Plumbing Work – Illegal/No Permit (also Sprinkler/Standpipe)

66

BACTIVE——
Apr 6, 2026

Construction Enforcement Work Order (DOB)

1X

BACTIVE——
Mar 19, 2026

Failure to Retain Water/Improper Drainage (LL103/89)

85

CACTIVE——
Mar 13, 2026

Certificate of Occupancy – None/Illegal/Contrary to CO

31

CACTIVE——
Feb 25, 2026

Work Without a Permit – Occupied Multiple Dwelling

7J

BCLOSEDFeb 26, 2026

Access denied - 2nd attempt

Feb 25, 2026

Boiler: Defective/Inoperative/No Permit

58

BCLOSEDApr 8, 2026

No violation warranted for complaint at time of inspection

Feb 20, 2026

Electrical Wiring: Defective/Exposed – In Progress

59

BCLOSEDFeb 27, 2026

Ecb violation served

Feb 20, 2026

Plumbing Work – Illegal/No Permit (also Sprinkler/Standpipe)

66

BCLOSEDApr 13, 2026

Inspector unable to gain access - 2nd attempt

Feb 15, 2026

Debris – Excessive

09

BCLOSEDMar 26, 2026

No violation warranted for complaint at time of inspection

Feb 6, 2026

Work Without a Permit – Occupied Multiple Dwelling

7J

BCLOSEDFeb 9, 2026

Inspector unable to gain access - 2nd attempt

Jan 18, 2026

Illegal Conversion

45

BCLOSEDMar 18, 2026

No violation warranted for complaint at time of inspection

Jan 5, 2026

Work Without a Permit – Occupied Multiple Dwelling

7J

BCLOSEDJan 6, 2026

Inspector unable to gain access - 2nd attempt

Jan 3, 2026

Plumbing Work – Illegal/No Permit (also Sprinkler/Standpipe)

66

BCLOSEDApr 13, 2026

Inspector unable to gain access - 2nd attempt

Dec 18, 2025

Construction Enforcement Work Order (DOB)

1X

BCLOSEDDec 19, 2025

No violation warranted for complaint at time of inspection

Dec 11, 2025

Certificate of Occupancy – None/Illegal/Contrary to CO

31

CCLOSEDDec 17, 2025

Please see complaint number

Nov 29, 2025

Illegal Hotel Rooms in Residential Buildings

4A

BCLOSEDFeb 12, 2026

Inspector unable to gain access - 2nd attempt

Nov 17, 2025

Unlicensed/Illegal/Improper Plumbing Work In-Progress

76

ACLOSEDNov 18, 2025

No violation warranted for complaint at time of inspection

Nov 17, 2025

Work Without a Permit – Occupied Multiple Dwelling

7J

BCLOSEDNov 17, 2025

No violation warranted for complaint at time of inspection

Nov 7, 2025

Debris/Building – Falling or In Danger of Falling

10

ACLOSEDNov 7, 2025

Ecb violation served

Oct 19, 2025

Illegal Conversion

45

BCLOSEDDec 17, 2025

Partial vacate order issued p

Oct 3, 2025

Construction Enforcement Work Order (DOB)

1X

BCLOSEDOct 6, 2025

No violation warranted for complaint at time of inspection

Oct 2, 2025

Building Under Structural Monitoring

2F

DCLOSEDOct 2, 2025N1
Oct 1, 2025

Building Shaking/Vibrating/Structural Stability Affected

30

ACLOSEDOct 2, 2025

Partial vacate order issued p

Jul 18, 2025

Illegal Conversion

45

BCLOSEDSep 9, 2025

No violation warranted for complaint at time of inspection

Jun 1, 2025

Boiler: Defective/Inoperative/No Permit

58

BCLOSEDJun 9, 2025

Inspector unable to gain access - 2nd attempt

May 23, 2025

Illegal Conversion

45

BCLOSEDJul 24, 2025

No violation warranted for complaint at time of inspection

May 14, 2025

Illegal Conversion

45

BCLOSEDJul 24, 2025

Ecb violation served

Apr 14, 2025

Illegal Conversion

45

BCLOSEDApr 28, 2025

Ecb violation served

Apr 10, 2025

Plumbing: Defective/Leaking/Not Maintained

94

CCLOSEDApr 11, 2025

Ecb violation served

Apr 26, 2022

Illegal Conversion

45

BCLOSEDOct 13, 2022

Inspector unable to gain access - 2nd attempt

Dec 21, 2021

Construction Enforcement Work Order (DOB)

1X

BCLOSEDDec 27, 2021

No violation warranted for complaint at time of inspection

Sep 30, 2021

Electrical Wiring: Defective/Exposed – In Progress

59

BCLOSEDOct 2, 2021

Ecb violation served

Sep 25, 2021

Certificate of Occupancy – None/Illegal/Contrary to CO

31

CCLOSEDNov 19, 2021

Inspector unable to gain access - 2nd attempt

Jul 19, 2021

Building Shaking/Vibrating/Structural Stability Affected

30

ACLOSEDJul 19, 2021

No violation warranted for complaint at time of inspection

Jul 16, 2021

Electrical Wiring: Defective/Exposed – In Progress

59

BCLOSEDJul 17, 2021

Ecb violation served

Jul 13, 2021

Boiler: Defective/Inoperative/No Permit

58

BCLOSEDJul 16, 2021

No violation warranted for complaint at time of inspection

Jun 7, 2021

Boiler: Defective/Inoperative/No Permit

58

BCLOSEDJun 9, 2021

Complaint referred to housing preservation and development (hpd)

May 21, 2021

Boiler: Defective/Inoperative/No Permit

58

BCLOSEDMay 27, 2021

No violation warranted for complaint at time of inspection

May 21, 2021

Electrical Wiring: Defective/Exposed – In Progress

59

BCLOSEDMay 24, 2021

Ecb violation served

Apr 19, 2021

Boiler: Defective/Inoperative/No Permit

58

BCLOSEDApr 26, 2021

Inspector unable to gain access - 2nd attempt

Mar 27, 2021

Boiler: Defective/Inoperative/No Permit

58

BCLOSEDMar 30, 2021

Ecb violation served

Mar 19, 2021

Boiler: Defective/Inoperative/No Permit

58

BCLOSEDMar 23, 2021

Complaint referred to housing preservation and development (hpd)

Feb 14, 2021

Boiler: Defective/Inoperative/No Permit

58

BCLOSEDFeb 19, 2021

Inspector unable to gain access - 2nd attempt

Feb 5, 2021

Boiler: Defective/Inoperative/No Permit

58

BCLOSEDFeb 12, 2021

No violation warranted for complaint at time of inspection

Jan 11, 2021

Electrical Wiring: Defective/Exposed – In Progress

59

BCLOSEDJan 12, 2021

Ecb violation served

Jan 11, 2021

Electrical Wiring: Defective/Exposed – In Progress

59

BCLOSEDJan 12, 2021

Ecb violation served

Apr 30, 2020

CSE: Sweep

7G

DCLOSEDJun 16, 2020

Stop work order fully rescinded n

Sep 26, 2019

Permit – None (Building/PA/Demo etc.)

05

BCLOSEDDec 23, 2019

Stop work order fully rescinded n

Page 1 of 2