| Class C | ClosedRENT IMPAIRING | — | Dec 2, 2025 | REMOVE ILLEGAL FASTENING · EGRESS§ 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING PADLOCK AND CHAIN AT METAL GATE AT FRONT AREAWAY |
| Class B | Open | 22 | Dec 2, 2025 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 4th ROOM FROM NORTH AT EAST LOCATED AT APT 22, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class B | Open | — | Dec 2, 2025 | REPAIR BROKEN PAYING · PAVING AND GRADING§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE PAVING CEMENT PAVING AT BUILDING REAR AND EAST YARD |
| Class B | ClosedRENT IMPAIRING | — | Dec 2, 2025 | PROVIDE A JANITOR · JANITORIAL SERVICES§ 27-2053 ADM CODE PROVIDE DWELLING WITH A JANITOR OR RESPONSIBLE PERSON OR JANITORIAL SERVICE. |
| Class A | Closed | — | Dec 2, 2025 | POST SIGN INDICATING NAME AND ADDRESS OF JANITOR, ETC. · POSTING/SIGNAGE§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. |
| Class A | Closed | — | Dec 2, 2025 | POST FLOOR SIGN · POSTING/SIGNAGE§ 27-2048 ADM CODE PAINT OR POST A SIGN INDICATING FLOORS AT ALL STORIES THROUGHOUT AT PUBLIC HALL, 4th STORY |
| Class A | Closed | — | Dec 2, 2025 | POST FLOOR SIGN · POSTING/SIGNAGE§ 27-2048 ADM CODE PAINT OR POST A SIGN INDICATING FLOORS AT ALL STORIES THROUGHOUT AT PUBLIC HALL, 3rd STORY |
| Class B | Open | 22 | Dec 2, 2025 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL IN THE FOYER LOCATED AT APT 22, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class A | Open | 11 | Dec 2, 2025 | FILE PLANS OR RESTORE · ALTERATIONS§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CONSISTING OF WALLS ERECTED FROM FLOOR TO CEILING SUBDIVIDING APARTMENT IN THE 6th ROOM FROM NORTH AT WEST LOCATED AT APT 11, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Open | — | Dec 2, 2025 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE GLASS AT METAL SCREEN AT BULKHEAD |
| Class B | Open | 22 | Dec 2, 2025 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT ALL WALLS IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 22, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class B | Open | 22 | Dec 2, 2025 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 22, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class B | ClosedRENT IMPAIRING | — | Dec 2, 2025 | REMOVE ENCUMBRANCES · EGRESS§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF DISCARDED CONSTRUCTION MATERIALS AT ROOF |
| Class A | Open | 11 | Dec 2, 2025 | FILE PLANS OR RESTORE · ALTERATIONS§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CONSISTING OF WALLS ERECTED FROM FLOOR TO CEILING SUBDIVIDING APARTMENT IN THE 6th ROOM FROM NORTH LOCATED AT APT 11, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class C | Open | 22 | Dec 2, 2025 | MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR IN THE ENTRANCE LOCATED AT APT 22, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class B | Open | 22 | Dec 2, 2025 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL AND WEST WALL IN THE BATHROOM LOCATED AT APT 22, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class B | Open | 22 | Dec 2, 2025 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL TILE FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 22, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class A | Open | 22 | Dec 2, 2025 | PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 22, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class B | Open | 22 | Dec 2, 2025 | ADJUST DOOR TO PREVENT GAP - FIRE CODE/EGRESS · EGRESS28 RCNY § 25-171; & 67 (7)(B) MDL; NYC FIRE CODE § 703.1.3; NYC FIRE CODE § 703.2: ADJUST DOOR TO PREVENT GAPS BETWEEN THE TOP AND SIDE EDGES OF DOOR AND DOOR JAMB EXCEEDING THE MAXIMUM ALLOWABLE CLEARANCE OF 1/8 OF AN INCH AND MAXIMUM ALLOWABLE CLEARANCE OF 3/4 OF AN INCH BETWEEN THE DOOR BOTTOM AND SILL AT ... IN THE ENTRANCE LOCATED AT APT 22, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | — | Dec 2, 2025 | REPLACE · MAINTENANCE§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING KNOB AT DOOR AT SOUTH WALL ALLOWING RE-ENTRY FROM ROOF TO BULKHEAD |
| Class B | Open | 22 | Dec 2, 2025 | REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WOOD FRAME AT DOOR IN THE ENTRANCE LOCATED AT APT 22, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class B | Open | 22 | Dec 2, 2025 | REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 22, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class C | OpenRENT IMPAIRING | 16 | Dec 1, 2025 | NO GAS · KITCHEN AND KITCHENETTES§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT COOKING RANGE IN THE KITCHEN LOCATED AT APT 16, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Class C | ClosedRENT IMPAIRING | 10 | Dec 1, 2025 | INADEQUATE HOT WATER · HEAT AND HOT WATER§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 10, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class A | Open | 6 | Dec 1, 2025 | PAINT METAL · PAINTING§ 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE RADIATOR AT WEST WALL IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 6, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | O | Dec 1, 2025 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD STOOL AT WINDOW AT NORTH WALL IN THE 3rd ROOM FROM NORTH AT WEST LOCATED AT APT O, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Class B | Closed | O | Dec 1, 2025 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 4th ROOM FROM NORTH LOCATED AT APT O, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Class A | Open | 6 | Dec 1, 2025 | PAINT METAL · PAINTING§ 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE RADIATOR AT SOUTH WALL IN THE 4th ROOM FROM NORTH AT WEST LOCATED AT APT 6, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class C | Closed | 4 | Dec 1, 2025 | ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOUSEHOLD ITEMS AT FIRE ESCAPE ACCESS WINDOW OBSTRUCTING SECONDARY EGRESS IN THE 1st ROOM FROM NORTH LOCATED AT APT 4, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Class B | Closed | 16 | Dec 1, 2025 | REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 16, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Class B | Closed | 16 | Dec 1, 2025 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 16, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Class C | ClosedRENT IMPAIRING | 6 | Dec 1, 2025 | NO GAS · KITCHEN AND KITCHENETTES§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT COOKING RANGE IN THE KITCHEN LOCATED AT APT 6, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 14 | Dec 1, 2025 | SECURE LOOSE MATTER · MAINTENANCE§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE ESCUTCHEON PLATE AT STEAM RISER AT CEILING IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 14, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 14 | Dec 1, 2025 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 14, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 6 | Dec 1, 2025 | REPLACE · MAINTENANCE§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING CONTROL VALVE AT RADIATOR AT SOUTH WALL IN THE 4th ROOM FROM NORTH AT WEST LOCATED AT APT 6, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 14 | Dec 1, 2025 | REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 14, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 20 | Dec 1, 2025 | REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION CEILING IN THE BATHROOM LOCATED AT APT 20, 6th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Class C | ClosedRENT IMPAIRING | 10 | Dec 1, 2025 | INADEQUATE HEAT · HEAT AND HOT WATER§ 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 10, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class C | Closed | — | Dec 1, 2025 | MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR LEADING TO BASEMENT AT PUBLIC HALL, 1st STORY |
| Class C | ClosedRENT IMPAIRING | 13 | Dec 1, 2025 | NO GAS · KITCHEN AND KITCHENETTES§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES TO RANGE IN THE ENTIRE APARTMENT LOCATED AT APT 13, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Class C | OpenRENT IMPAIRING | 14 | Dec 1, 2025 | NO GAS · KITCHEN AND KITCHENETTES§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT COOKING RANGE IN THE KITCHEN LOCATED AT APT 14, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 6 | Dec 1, 2025 | REPLACE · MAINTENANCE§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING CONTROL KNOB AT RADIATOR AT WEST WALL IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 6, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class C | Closed | 14 | Dec 1, 2025 | MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR IN THE ENTRANCE LOCATED AT APT 14, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class C | Closed | — | Dec 1, 2025 | PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BASEMENT AT BOILER ROOM |
| Class C | ClosedRENT IMPAIRING | 13 | Dec 1, 2025 | INADEQUATE HOT WATER · HEAT AND HOT WATER§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 13, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Class A | Open | 20 | Dec 1, 2025 | FILE PLANS OR RESTORE · ALTERATIONS§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CONSISTING OF WALLS ERECTED WITH STUDS AND SHEET ROCK CREATING ADDITIONAL ROOM IN THE 5th ROOM FROM NORTH LOCATED AT APT 20, 6th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Class A | Open | 20 | Dec 1, 2025 | FILE PLANS OR RESTORE · ALTERATIONS§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CONSISTING OF WALLS ERECTED WITH STUDS AND SHEET ROCK CREATING ADDITIONAL ROOM IN THE 2nd ROOM FROM NORTH LOCATED AT APT 20, 6th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Class A | Open | 6 | Dec 1, 2025 | PAINT METAL · PAINTING§ 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE RADIATOR AT WEST WALL IN THE KITCHEN LOCATED AT APT 6, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class C | Closed | 10 | Dec 1, 2025 | MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 10, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class C | Closed | — | Dec 1, 2025 | PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM IN CELLAR DOOR LOCKED AT BOILER ROOM |