Manhattan · ZIP 10037 · BIN 1053936 · Harlem (North) · Last violation May 14, 2026 · Last complaint May 28, 2026

NeighborhoodHarlem (North)
Above-average violations for the neighborhood
More violations than 76% of buildings and more complaints than 84% of buildings in Harlem (North). Size-normalized against residential buildings in the neighborhood for issues in the last 10 years.
ViolationsComplaints
Activity TrendsLast 5 years
A steady level of activity over time
Last 2 yrs: 197 violations · 410 complaints
'21'26ViolationsComplaints
▼ View all activity over time
Severityⓘopen violations
12 immediately hazardous (Class C) violations still open
Class C violations include lead paint, mold, pest infestations, heat/hot water failure, and structural hazards — the most serious category.
Class Cimmediately hazardous12Class Bhazardous24
Housing Preservation & Development Violations
Total violations since 2000
1,075
40 per year avg.↓ Down 37% in the last 2 years (197 vs 311 prior 2 yrs)
Open violations
37
Class C (immed. haz.)ⓘ12
Class B (hazardous)ⓘ24
Rent-impairingⓘ1
Housing Preservation & Development Complaints
Total complaints since 2003
2,689
112 per year avg.→ Stable in the last 2 years
Complaint Resolution
No access17%Violation issued18%No violation29%Phone resolved36%Other0%(2,689)
Urgency breakdown
Last 12 mo.

Top violation categories

5 yrsAll time
Maintenanceⓘ226 violations
Egressⓘ109 violations
Extermination & Rodent Eradicationⓘ45 violations
Water Supplyⓘ44 violations
Carbon Monoxide Detecting Devicesⓘ33 violations
Smoke Detecting Devicesⓘ33 violations
Paintingⓘ31 violations
Cleaningⓘ24 violations
Top complaint groupsⓘ
5 yrsAll time
Heat / hot waterⓘ340 complaints
Water & plumbingⓘ219 complaints
Bldg maintenanceⓘ157 complaints
Mold & pestsⓘ130 complaints
Electricalⓘ35 complaints
Appliancesⓘ34 complaints
Safety & fireⓘ22 complaints
Adminⓘ1 complaints
Hide violations ↑See complaints →

Violation log

1,038 violations · Close

All classesClass AClass BClass CClass IAllOpenClosed
ClassStatusApt

Building safety complaints, construction, permits, and structural issues filed with the NYC Dept. of Buildings, are scored separately.

Building Safety →
See something wrong? File a complaint with 311
Open violation ages
▪ 30–90 days16% (6)
▪ 3–12 months3% (1)
▪ 1–3 years54% (20)
▪ 3+ years27% (10)
Prior 4 yr.
Immed. Emergency3%6%
Emergency59%57%
Non-Emergency37%36%
(174)
(903)
Issued
Description
Class AClosed9GMar 18, 2022PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT ALL WALLS IN THE KITCHEN LOCATED AT APT 9G, 9th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class CClosedRENT IMPAIRING9GMar 18, 2022REMOVE OBSTUCTION FROM WATER CLOSET · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS FROM WATER CLOSET ... IN THE BATHROOM LOCATED AT APT 9G, 9th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BClosed9GMar 18, 2022REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL FINISH BY METHOD OF REGLAZING AT BATHTUB IN THE BATHROOM LOCATED AT APT 9G, 9th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BClosed9GMar 18, 2022REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER WINDOW SASH AT EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 9G, 9th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class AClosed9GMar 18, 2022REFIT DOORS ETC. · EGRESS§ 27-2005 ADM CODE REFIT THE ENTRANCE DOOR IN THE BATHROOM LOCATED AT APT 9G, 9th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BClosed9GMar 18, 2022REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 9G, 9th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BClosed9GMar 18, 2022REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 9G, 9th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BClosed9GMar 18, 2022REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 9G, 9th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class AClosed—Feb 15, 2022FILE ANNUAL BEDBUG REPORT · FILING: BEDBUGS(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
Class AClosed15JDec 20, 2021REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE DOOR IN THE ENTRANCE LOCATED AT APT 15J, 15th STORY, 5th APARTMENT FROM NORTH AT EAST
Class AClosed—Dec 20, 2021REFIT DOORS ETC. · EGRESS§ 27-2005 ADM CODE REFIT DOOR AT SOUTH TO B- STAIRWAY AT FIRE STAIRS, 8th STORY
Class AClosed15JDec 20, 2021REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL, RETURN BUZZER AND INTERCOM SYSTEM FROM FRONT BUILDING ENTRANCE DOOR TO APARTMENT LOCATED AT APT 15J, 15th STORY, 5th APARTMENT FROM NORTH AT EAST
Class BClosed6DNov 22, 2021REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CONCRETE FLOOR IN THE 1st ROOM FROM NORTH AT CENTER LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM WEST AT NORTH
Class AClosed6DNov 22, 2021TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING APPRX 4 SQUARE FEET IN THE BATHROOM LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM WEST AT NORTH
Class CClosed6DNov 22, 2021MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .. IN THE ENTRANCE LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed6DNov 22, 2021REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed6DNov 22, 2021REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed—Nov 22, 2021REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE FOR FIXTURE AT CEILING AT PUBLIC HALL STAIRS, 7th STORY
Class AClosed15JNov 22, 2021TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING APPRX 2 SQAURE FEET IN THE BATHROOM LOCATED AT APT 15J, 15th STORY, 1st APARTMENT FROM NORTH AT EAST
Class AClosed15JNov 22, 2021PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 15J, 15th STORY, 1st APARTMENT FROM NORTH AT EAST
Class BClosed6DNov 22, 2021REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE DOOR KNOB IN THE ENTRANCE LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed15ANov 22, 2021REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL, RETURN BUZZER AND INTERCOM SYSTEM FROM. FRONT OF BUILDING TO IN THE ENTIRE APARTMENT LOCATED AT APT 15A, 15th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class AClosed15JNov 22, 2021PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT EAST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 15J, 15th STORY, 1st APARTMENT FROM NORTH AT EAST
Class BClosedLDNov 22, 2021REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM NORTH AT CENTER LOCATED AT BSMT-APT LD
Class AClosed6DNov 22, 2021PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS IN THE BATHROOM LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM WEST AT NORTH
Class AClosed6DNov 22, 2021PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND ALL WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosedLDNov 22, 2021REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM NORTH AT CENTER LOCATED AT APT LD, 1st APARTMENT FROM NORTH AT EAST
Class BClosed15JNov 22, 2021REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT FLOOR IN THE BATHROOM LOCATED AT APT 15J, 15th STORY, 1st APARTMENT FROM NORTH AT EAST
Class BClosedLDNov 22, 2021REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM NORTH LOCATED AT BSMT-APT LD
Class AClosed15JNov 4, 2021REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WEST WALL IN THE BATHROOM LOCATED AT APT 15J, 15th STORY, 5th APARTMENT FROM NORTH AT EAST
Class CClosed15JNov 4, 2021MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 2007, 204.1 HMC CODE: REPLACE OR REPAIR THE SELF-CLOSING THE DOORS THAT IS MISSING OR DEFECTIVE .. IN THE ENTRANCE LOCATED AT APT 15J, 15th STORY, 5th APARTMENT FROM NORTH AT EAST
Class AClosed15JNov 4, 2021REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL BUZZER FROM STREET ENTRANCE TO THE APARTMENT IN THE FOYER LOCATED AT APT 15J, 15th STORY, 5th APARTMENT FROM NORTH AT EAST
Class BClosed15JNov 4, 2021REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 15J, 15th STORY, 5th APARTMENT FROM NORTH AT EAST
Class AClosed15JNov 4, 2021REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL IN THE FOYER LOCATED AT APT 15J, 15th STORY, 5th APARTMENT FROM NORTH AT EAST
Class BClosed15JNov 4, 2021REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 15J, 15th STORY, 5th APARTMENT FROM NORTH AT EAST
Class AClosed15JNov 4, 2021REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 15J, 15th STORY, 5th APARTMENT FROM NORTH AT EAST
Class CClosed15AOct 14, 2021MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ..... IN THE ENTRANCE LOCATED AT APT 15A, 15th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed15AOct 14, 2021REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCKING MECHANISM TO THE DOOR IN THE ENTRANCE LOCATED AT APT 15A, 15th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class AClosed9GOct 5, 2021REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE SPRING BALANCE TO LOWER WINDOW SASH IN THE 1st ROOM FROM EAST LOCATED AT APT 9G, 9th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed9GOct 5, 2021REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CLOSET SHELVES AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 9G, 9th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed9GOct 5, 2021REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND WALLS IN THE BATHROOM LOCATED AT APT 9G, 9th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class AClosed9GOct 5, 2021PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILINGS AND WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 9G, 9th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class CClosed16AOct 5, 2021REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 16A, 16th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class AClosed9GOct 5, 2021REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL FINISH BY METHOD OF REGLAZING AT BATHTUB IN THE BATHROOM LOCATED AT APT 9G, 9th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosedRENT IMPAIRING9GOct 5, 2021REPAIR FLUSHING APPARATUS OF WATER CLOSET · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET ...... IN THE BATHROOM LOCATED AT APT 9G, 9th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class AClosed15POct 5, 2021REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE CABINET DRAWER AT WEST WALL IN THE KITCHEN LOCATED AT APT 15P, 15th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosedRENT IMPAIRING16AOct 5, 2021LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE BATHROOM LOCATED AT APT 16A, 16th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed9GOct 5, 2021REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL THE WALLS OF THE CLOSET IN THE PRIVATE HALLWAY LOCATED AT APT 9G, 9th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class AClosed16AOct 5, 2021REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND INTERIOR WINDOW FRAME IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 16A, 16th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed9GOct 5, 2021REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND WALLS IN THE 1st ROOM FROM EAST LOCATED AT APT 9G, 9th STORY, 2nd APARTMENT FROM SOUTH AT WEST