stoop
Map
LeaderboardAbout
Building SafetyHousing Conditions

162 WEST 132 STREET

Manhattan · ZIP 10027 · BIN 1058118 · Harlem (North) · Last violation May 7, 2026 · Last complaint May 6, 2026

NeighborhoodHarlem (North)
More violations than 100% of nearby buildings
More violations than 100% of buildings and more complaints than 100% of buildings in Harlem (North). Size-normalized against residential buildings in the neighborhood for issues in the last 10 years.
ViolationsComplaints
Activity TrendsLast 5 years
A steady level of activity over time
Last 2 yrs: 42 violations · 441 complaints
'21'26ViolationsComplaints
▼ View all activity over time
Severityⓘopen violations
105 immediately hazardous (Class C) violations still open
Class C violations include lead paint, mold, pest infestations, heat/hot water failure, and structural hazards — the most serious category.
Class Cimmediately hazardous105Class Bhazardous261
Housing Preservation & Development Violations
Total violations since 2007
942
47 per year avg.↓ Down 83% in the last 2 years (42 vs 249 prior 2 yrs)
Open violations
421
Class C (immed. haz.)ⓘ105
Class B (hazardous)ⓘ261
Rent-impairingⓘ58
Housing Preservation & Development Complaints
Total complaints since 2004
1,796
78 per year avg.→ Stable in the last 2 years
Complaint Resolution
No access22%Violation issued14%No violation46%Phone resolved16%Other1%(1,796)
Urgency breakdown
Last 12 mo.

Top violation categories

5 yrsAll time
Maintenanceⓘ161 violations
Cleaningⓘ35 violations
Extermination & Rodent Eradicationⓘ26 violations
Egressⓘ25 violations
Water Supplyⓘ22 violations
Sewers And Drainageⓘ22 violations
Carbon Monoxide Detecting Devicesⓘ20 violations
Heat And Hot Waterⓘ18 violations
Top complaint groupsⓘ
5 yrsAll time
Mold & pestsⓘ190 complaints
Water & plumbingⓘ187 complaints
Bldg maintenanceⓘ169 complaints
Heat / hot waterⓘ163 complaints
Electricalⓘ98 complaints
Safety & fireⓘ49 complaints
Appliancesⓘ32 complaints
Adminⓘ9 complaints
Outdoor / structuralⓘ6 complaints
Elevatorⓘ2 complaints
Hide violations ↑See complaints →

Violation log

521 violations · Close

All classesClass AClass BClass CClass IAllOpenClosed
ClassStatusApt

Building safety complaints, construction, permits, and structural issues filed with the NYC Dept. of Buildings, are scored separately.

Building Safety →
See something wrong? File a complaint with 311
Open violation ages
▪ < 30 days0% (1)
▪ 30–90 days0% (2)
▪ 3–12 months2% (10)
▪ 1–3 years27% (112)
▪ 3+ years70% (292)
Prior 4 yr.
Immed. Emergency2%5%
Emergency52%55%
Non-Emergency46%40%
(239)
(812)
Issued
Description
Class BClosed1Mar 9, 2017REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE KITCHEN LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EAST
Class BClosed1Mar 9, 2017ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATION§ 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EAST
Class BClosed1Mar 9, 2017REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EAST
Class BClosed—Feb 9, 2016REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MAILBOXES AT VESTIBULE AT PUBLIC HALL, 1st STORY
Class BClosed6Jan 25, 2016REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHENETTE LOCATED AT APT 6, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST
Class CClosed6Jan 25, 2016REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE KEY OPERATED LOCK AT DOOR IN THE ENTRANCE LOCATED AT APT 6, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST
Class CClosed6Jan 25, 2016REPAIR BROKEN, LOOSE CONNECTION · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT RADIATOR SHUT OFF VALVE IN THE 2nd ROOM FROM NORTH LOCATED AT APT 6, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST
Class CClosedRENT IMPAIRING—Dec 22, 2015LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING AT PUBLIC HALL, 3rd STORY
Class CClosed—Dec 22, 2015REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE TREAD 2ND UP FROM BOTTOM AT PUBLIC HALL, 2nd STORY
Class BClosedRENT IMPAIRING—Dec 22, 2015REMOVE ENCUMBRANCES · EGRESS§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS ON STAIRCASE LEADING TO BASEMENT AT PUBLIC HALL, 1st STORY
Class CClosed—Dec 22, 2015REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT PUBLIC HALL, 2nd STORY
Class BClosed—Dec 22, 2015PROVIDE · MAINTENANCE§ 27-2005 ADM CODE PROVIDE SCREEN AT SKYLIGHT AT PUBLIC HALL, 3rd STORY
Class CClosed—Dec 22, 2015REPAIR/ABATE UNSAFE WIRES · ARTIFICIAL LIGHTING§ 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED WIRES AT WEST WALL AT PUBLIC HALL, 1st STORY
Class CClosedRENT IMPAIRING6Jul 29, 2015LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 6, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH
Class CClosedRENT IMPAIRING6Jul 28, 2015LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 6, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH
Class BClosed—Jul 24, 2015SCUTTLE LADDER NOT STATIONARY · EGRESS§ 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. MAKE STATIONARY THE IRON LADDER LEADING TO SCUTTLE OPENING IN ROOF .... AT PUBLIC HALL, 3rd STORY
Class CClosedRENT IMPAIRING6Jul 24, 2015NO GAS · KITCHEN AND KITCHENETTES§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES ... IN THE KITCHENETTE LOCATED AT APT 6, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH
Class BClosed6Jul 24, 2015MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ... IN THE ENTRANCE LOCATED AT APT 6, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH
Class BClosedRENT IMPAIRING—Jul 24, 2015REMOVE ENCUMBRANCES · EGRESS§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT STAIRS LEADING TO BASEMENT AT PUBLIC HALL, 1st STORY
Class CClosedRENT IMPAIRING—Jul 24, 2015LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT SKYLIGHT AT PUBLIC HALL, 3rd STORY
Class BClosed—Oct 24, 2014REMOVE ACCUMULATION OR RUBBISH · CLEANING§ 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE ENTIRE PUBLIC HALL STAIRS FROM BASEMENT TO 1ST. STY PUBLIC HALL
Class CClosed—Jan 13, 2014REPAIR · MAINTENANCESECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INOPERATIVE WOOD SCUTTLE COVER AT PUBLIC HALL, 3rd STORY
Class BClosed—Jan 13, 2014SCUTTLE LADDER NOT STATIONARY · EGRESS§ 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. MAKE STATIONARY THE IRON LADDER LEADING TO SCUTTLE OPENING IN ROOF ... AT PUBLIC HALL, 3rd STORY
Class CClosedGROUNDJan 13, 2014PROVIDE ADEQUATE HEAT · HEAT AND HOT WATERSECTION 27-2028, 2032 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FROM AN APPROVED CENTRAL HEATING SYSTEM, OR AN APPROVED SYSTEM OF GAS OR ELECTRICAL HEATING IN GOOD OPERATING CONDITION FOR THE DWELLING UNIT IN THE ENTIRE APARTMENT LOCATED AT APT GROUND, 1st APARTMENT FROM NORTH AT EAST
Class CClosedRENT IMPAIRINGGROUNDJan 13, 2014INADEQUATE HOT WATER · HEAT AND HOT WATER§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT GROUND, 1st APARTMENT FROM NORTH AT EAST
Class CClosed2Jan 7, 2014PROVIDE ADEQUATE HEAT · HEAT AND HOT WATERSECTION 27-2028, 2032 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FROM AN APPROVED CENTRAL HEATING SYSTEM, OR AN APPROVED SYSTEM OF GAS OR ELECTRICAL HEATING IN GOOD OPERATING CONDITION FOR THE DWELLING UNIT IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY
Class CClosedRENT IMPAIRING—Jan 7, 2014NO GAS · KITCHEN AND KITCHENETTESSECTION 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES THROUGH OUT ENTIRE BUILDING
Class CClosed—Jan 7, 2014REMOVE ACCUMULATION OR RUBBISH · CLEANINGSECTION 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE ENTIRE FLOOR AREA AT CELLAR
Class CClosedRENT IMPAIRING2Jan 7, 2014INADEQUATE HOT WATER · HEAT AND HOT WATERSECTION 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY
Class CClosedRENT IMPAIRINGGJan 2, 2014INADEQUATE HOT WATER · HEAT AND HOT WATERSECTION 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT G, APARTMENT AT EAST
Class CClosed—Jan 2, 2014REPAIR/ABATE UNSAFE WIRES · ARTIFICIAL LIGHTING§ 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXSPOSED ELECTRICAL WIRE AT NORTH WALL AT PUBLIC HALL
Class CClosedRENT IMPAIRINGGJan 2, 2014INADEQUATE HEAT · HEAT AND HOT WATERSECTION 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT G, APARTMENT AT EAST
Class CClosed—Jan 2, 2014PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM .. AT PUBLIC HALL
Class CClosed—Apr 26, 2013RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE 2 PAINTED SPRINKLER HEADS AT PUBLIC HALL, 3rd STORY
Class CClosed—Apr 26, 2013REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PLASTER AT COCKLOFT AT ALL WALLS AND CEILING AT PUBLIC HALL, 3rd STORY
Class CClosed—Apr 26, 2013RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE 1 PAINTED SPRINKLER HEAD AT PUBLIC HALL, 1st STORY
Class CClosed—Apr 26, 2013REPLACE · MAINTENANCE§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING MISSING SKYLIGHT AT PUBLIC HALL, 3rd STORY
Class AClosed—Mar 20, 2013POST SMOKE DETECTOR NOTICE · POSTING/SIGNAGE§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX , AT LOBBY, 1st STORY
Class AClosed—Mar 20, 2013NO MAIL RECEPTACLES · MISCELLANEOUS SERVICES AND FACILITIES§ 27-2047 ADM CODE PROVIDE AND MAINTAIN APPROVED MAIL RECEPTACLES AND DIRECTORIES FOR THE PERSONS RESIDING IN THE DWELLING AS PROVIDED IN THE U.S. POSTAL REGULATIONS. AT LOBBY, 1st STORY
Class AClosed—Mar 20, 2013POST CO DETECTOR NOTICE · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT LOBBY, 1st STORY
Class AClosed—Mar 20, 2013IV-1. MAILBOXES PRESENT · POSTING/SIGNAGE§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR , AT LOBBY, 1st STORY
Class BClosedRENT IMPAIRING—Mar 15, 2013FIRE RETARD CELLAR CEILING · FIRE EGRESS AND PROTECTION§ 185, 240 M/D LAW PROPERLY FIRE RETARD IN ACCORDANCE WITH THE RULES AND REGULATIONS OF THIS DEPARTMENT THE CELLAR CEILING , AT CELLAR
Class BClosedRENT IMPAIRING—Mar 15, 2013LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING AT PUBLIC HALL, 3rd STORY
Class AClosed—Mar 15, 2013PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILINGS AT ALL STORIES AT PUBLIC HALL
Class BClosed—Mar 15, 2013REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDING MATERIAL AT THE WALLS AND CEILINGS AT ALL STORIES AT PUBLIC HALL
Class BClosed—Mar 15, 2013PROVIDE Adequate LIGHT · ARTIFICIAL LIGHTING§ 27-2037 ADM CODE PROVIDE ADEQUATE LIGHTING THROUGHOUT AT CELLAR
Class BClosed—Mar 15, 2013REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDING MATERIAL AT THE WALLS AROUND THE SCUTTLE OPENING AT PUBLIC HALL, 3rd STORY
Class CClosed—Mar 15, 2013RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIREDSECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE PAINTED SPRINKLER HEAD AT PUBLIC HALL STAIRS, 1st STORY
Class BClosed—Mar 15, 2013REPLACE · MAINTENANCE§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRICAL OUTLET COVER ON THE SOUTH WALL AT THE PUBLIC HALL AT BASEMENT
Class CClosed—Mar 15, 2013REPAIR WITH SIMILAR MATERIAL · MAINTENANCESECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD 1ST TO THE 6TH TREADS FROM THE BOTTOM UP AT THE STAIRS TO THE AT CELLAR
Page 9 of 11