| Class A | Open | 5B | Jul 29, 2013 | PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE FOYER , THE KITCHEN , THE BATHROOM , THE 3rd ROOM FROM NORTH AT WEST, THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 5B, 5th STORY, 6th APARTMENT FROM NORTH AT EAST |
| Class B | Closed | 5B | Jul 24, 2013 | REPAIR/ABATE UNSAFE WIRES · ARTIFICIAL LIGHTING§ 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL BX CABLE AT WALLS AND CEILING AT WEST 1 CLOSET IN THE FOYER LOCATED AT APT 5B, 5th STORY, 6th APARTMENT FROM NORTH AT EAST |
| Class B | Closed | 6L | Jul 24, 2013 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS IN THE FOYER LOCATED AT APT 6L, 6th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Class C | Closed | 5B | Jul 24, 2013 | INSTALL/REPLACE/REPAIR WINDOW GUARDS (APT) · WINDOW GUARDS§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 2; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th STORY, 6th APARTMENT FROM NORTH AT EAST |
| Class B | Open | 5B | Jul 24, 2013 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE UNEVEN WOOD FLOOR IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 5B, 5th STORY, 6th APARTMENT FROM NORTH AT EAST |
| Class B | Closed | 6L | Jul 24, 2013 | NO CO DETECTOR OR DETECTOR NOT OPERATIONAL · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 6L, 6th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Class C | Closed | 6L | Jul 24, 2013 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 6L, 6th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Class B | Closed | 2D | Jun 27, 2013 | ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF LOCKABLE SLIDE BOLT IN THE ENTRANCE LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 2D | Jun 27, 2013 | NO CO DETECTOR OR DETECTOR NOT OPERATIONAL · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 2D | Jun 27, 2013 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 2D | Jun 27, 2013 | REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER SASH WINDOW IN THE 2nd ROOM FROM EAST LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class B | Open | 6C | Jun 24, 2013 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 6C, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | OpenRENT IMPAIRING | 6C | Jun 24, 2013 | LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 6C, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | — | Jun 4, 2013 | ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATION§ 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES AT LAUNDRY ROOM |
| Class A | Open | 5B | Apr 15, 2013 | PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 1st DOOR FRAME FROM WEST AT NORTH WALL IN THE 1st PRIVATE HALLWAY FROM EAST LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST |
| Class A | Open | 5B | Apr 15, 2013 | PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING, EAST WALL IN THE 3rd ROOM FROM NORTH AT WEST LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST |
| Class A | Open | 5B | Apr 15, 2013 | PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 1st DOOR FRAME FROM SOUTH AT WEST WALL IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST |
| Class A | Open | 5B | Apr 15, 2013 | PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 1st CLOSET FROM SOUTH AT WEST WALL DOOR FRAME, 1st DOOR FRAME FROM SOUTH AT WEST WALL IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST |
| Class C | Closed | — | Mar 27, 2013 | PROVIDE · MAINTENANCE§ 27-2005 ADM CODE PROVIDE ACCEPTABLE MECHANICAL HEAVY DUTY LOCK AND LATCH SET AT THE BUILDING ENTRANCE DOOR AT VESTIBULE , 1st STORY |
| Class C | Closed | 5B | Mar 25, 2013 | LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM SOUTH AT WEST WALL IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST |
| Class C | Closed | 5B | Mar 25, 2013 | LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING, EAST WALL IN THE 3rd ROOM FROM NORTH AT WEST LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST |
| Class C | Closed | 5B | Mar 25, 2013 | LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM WEST AT NORTH WALL IN THE 1st PRIVATE HALLWAY FROM EAST LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST |
| Class C | Closed | 5B | Mar 25, 2013 | LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st CLOSET FROM SOUTH AT WEST WALL DOOR FRAME, 1st DOOR FRAME FROM SOUTH AT WEST WALL IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST |
| Class B | Closed | 5B | Mar 18, 2013 | REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK WATER PENETRATION FROM EXTERIOR OF WEST WALL IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST |
| Class B | Closed | 5B | Mar 18, 2013 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WALLS IN THE 3rd ROOM FROM NORTH AT WEST LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST |
| Class C | Open | 5B | Mar 18, 2013 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING CEILING IN THE 3rd ROOM FROM NORTH AT WEST LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST |
| Class B | Closed | 5B | Mar 18, 2013 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WEST WALL IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST |
| Class B | Open | 5B | Mar 18, 2013 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE HARD WOOD FLOOR IN THE 3rd ROOM FROM NORTH AT WEST LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST |
| Class B | Closed | 5B | Mar 18, 2013 | RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE AIR VALVE AND SHUT OFF VALVE AT RADIATOR IN THE 3rd ROOM FROM NORTH AT WEST LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST |
| Class C | ClosedRENT IMPAIRING | 5B | Mar 18, 2013 | REPAIR FLUSHING APPARATUS OF WATER CLOSET · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET , IN THE BATHROOM LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST |
| Class B | Closed | 5B | Mar 18, 2013 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... CEILING AND EAST WALL ( 20 SQUARE FEET.) IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST |
| Class A | Closed | 5D | Mar 13, 2013 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS IN THE 2nd ROOM FROM EAST LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 5D | Mar 13, 2013 | SECURE LOOSE MATTER · MAINTENANCE§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE ELECTRICAL OUTLET AT SOUTH WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 5D | Mar 13, 2013 | ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATION§ 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class A | Closed | 5D | Mar 13, 2013 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILING IN THE 4th ROOM FROM EAST AT NORTH LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 5D | Mar 13, 2013 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL AROUND BREAKER BOX IN THE FOYER LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class A | Closed | 5D | Mar 13, 2013 | PAINT METAL · PAINTING§ 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION RADIATOR IN THE 4th ROOM FROM EAST AT NORTH LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class A | Closed | 5D | Mar 13, 2013 | PAINT METAL · PAINTING§ 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION RADIATOR IN THE 4th ROOM FROM EAST AT SOUTH LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class A | Closed | 5D | Mar 13, 2013 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILING IN THE 4th ROOM FROM EAST AT SOUTH LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 5D | Jan 18, 2013 | REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT UPPER WINDOW SASH IN THE 4th ROOM FROM NORTH AT WEST LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 5D | Jan 18, 2013 | REPAIR/ABATE UNSAFE WIRES · ARTIFICIAL LIGHTING§ 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT SOUTH WALL IN THE 4th ROOM FROM NORTH AT WEST LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 5D | Jan 18, 2013 | REPAIR/ABATE UNSAFE WIRES · ARTIFICIAL LIGHTING§ 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | ClosedRENT IMPAIRING | 5D | Jan 18, 2013 | REPAIR FLUSHING APPARATUS OF WATER CLOSET · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET .. IN THE BATHROOM LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 5D | Jan 18, 2013 | REPAIR LEAKY FAUCETS · WATER SUPPLY§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class C | Closed | — | Jan 14, 2013 | REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK AND ASSEMBLY AT VESTIBULE DOOR , 1st STORY |
| Class C | Closed | — | Jan 2, 2013 | REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK AND ASSEMBLY AT BUILDING ENTRANCE DOOR , 1st STORY |
| Class A | Closed | — | Aug 1, 2012 | PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILING AT LAUNDRY AREA AT BASEMENT |
| Class C | Closed | 5B | Jun 21, 2012 | LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING IN THE 3rd ROOM FROM NORTH AT CENTER LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 5B | Jun 18, 2012 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | — | Jun 8, 2012 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDINTANT WALLS AND CEILING AT PUBLIC HALL |