| Class B | Open | 6M | May 28, 2026 | REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 6M, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH |
| Class C | Open | 6M | May 28, 2026 | DOOR NOT SELF-CLOSING · EGRESS§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING CONSISTING OF A WEATHER STRIP INSTALLED ON APARTMENT DOOR IN THE ENTRANCE LOCATED AT APT 6M, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH |
| Class B | Open | 6M | May 28, 2026 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 6M, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH |
| Class B | Open | — | Apr 22, 2026 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT CEILING AT COMMUNITY BATHROOM, 1st STORY ORIGINAL VIOLATION 18524765 ISSUED 22-DEC-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3)(a) or (b). |
| Class B | Open | 6S | Apr 7, 2026 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS THAT DEFFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6S, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH'' |
| Class A | Open | 4C | Apr 7, 2026 | PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING IN THE BATHROOM LOCATED AT APT 4C, 4th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH'' |
| Class B | Open | 6S | Apr 7, 2026 | REPLACE · MAINTENANCE§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING TANK COVER AT WATER CLOSET IN THE BATHROOM LOCATED AT APT 6S, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH'' |
| Class B | Open | 6S | Apr 7, 2026 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD BASE CABINET UNDER SINK IN THE KITCHEN LOCATED AT APT 6S, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH'' |
| Class B | Open | 6S | Apr 7, 2026 | REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES THAT DEFFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6S, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH'' |
| Class B | Open | 6S | Apr 7, 2026 | REPLACE · MAINTENANCE§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING CLOSET DOOR AT NORTH WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 6S, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH'' |
| Class B | Open | 6S | Apr 7, 2026 | REPAIR/ABATE UNSAFE WIRES · ARTIFICIAL LIGHTING§ 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED WIRES AT SOUTH WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 6S, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH'' |
| Class B | Open | 6P | Apr 6, 2026 | REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK SOUTH WALL IN THE BATHROOM LOCATED AT APT 6P, 6th STORY, 4th APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' |
| Class B | Open | 6P | Apr 6, 2026 | SECURE LOOSE MATTER · MAINTENANCE§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE CERAMIC TILES ABOVE THE BATHTUB AT NORTH WALL IN THE BATHROOM LOCATED AT APT 6P, 6th STORY, 4th APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' |
| Class B | Open | 6M | Mar 24, 2026 | REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 6M, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' |
| Class C | Open | 6M | Mar 24, 2026 | ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 6M, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' |
| Class B | Open | 6M | Mar 24, 2026 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 6M, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' |
| Class B | Closed | — | Mar 12, 2026 | ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF LATCH SET AND IT'S ASSEMBLIES AT HOPPER DOOR AT COMPACTOR CLOSET, 6th STORY |
| Class B | Open | 6R | Mar 12, 2026 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 6R, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Class C | Open | 6R | Mar 12, 2026 | ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 6R, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Class C | Closed | — | Mar 12, 2026 | MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH ON THE HOPPER DOOR AT COMPACTOR CLOSET, 6th STORY |
| Class A | Open | 6R | Mar 12, 2026 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 6R, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Class B | Open | 6S | Feb 10, 2026 | REMOVE BARS OR GATES FROM NON FIRE ESCAPE WINDOW · EGRESS§ 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM AT LEAST 1 WINDOW OR PROVIDE APPROVED TYPE GATE WINDOW GUARDS IN THE 1st ROOM FROM NORTH LOCATED AT APT 6S, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Class B | Open | 6S | Feb 10, 2026 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS THAT IS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6S, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Class B | Open | 6S | Feb 10, 2026 | REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DRAWER AT WEST WALL BASE CABINET IN THE KITCHEN LOCATED AT APT 6S, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | — | Dec 23, 2025 | REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE VENTILATION SYSTEM AT CEILING AT COMMUNITY BATHROOM, 1st STORY |
| Class A | Closed | — | Dec 23, 2025 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT CEILING AT COMMUNITY BATHROOM, 1st STORY |
| Class B | Closed | — | Dec 23, 2025 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AT COMMUNITY BATHROOM, 1st STORY |
| Class B | Closed | — | Dec 23, 2025 | REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT COMMUNITY BATHROOM, 1st STORY |
| Class C | ClosedRENT IMPAIRING | 6R | Jun 27, 2025 | INADEQUATE HOT WATER · HEAT AND HOT WATER§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 6R, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH'' |
| Class C | Open | — | Jun 27, 2025 | MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT BUILDING ENTRANCE DOOR ( FROM STREET TO VESTIBULE ) AT 1ST STORY , 1st STORY |
| Class B | Open | — | Jun 27, 2025 | REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AT BUILDING ENTRANCE DOOR ( FROM STREET TO VESTIBULE ) AT 1ST STORY , 1st STORY |
| Class C | Open | — | Jun 27, 2025 | PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM |
| Class B | Open | 6M | Apr 28, 2025 | REFIT DOORS ETC. · EGRESS§ 27-2005 HMC: REFIT DOOR AT FRAME IN THE ENTRANCE LOCATED AT APT 6M, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''South'' |
| Class B | Open | 6M | Apr 28, 2025 | ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF GAP BETWEEN FLOOR AND EAST WALL UNDER BASEBOARD IN THE 1st ROOM FROM EAST LOCATED AT APT 6M, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''South'' |
| Class B | Open | 6S | Apr 14, 2025 | REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOCK AND IT'S ASSEMBLIES AT THE DOOR IN THE ENTRANCE LOCATED AT APT 6S, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT SOUTH |
| Class B | ClosedRENT IMPAIRING | — | Feb 19, 2025 | INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT WASH BASIN AT COMMUNITY BATHROOM, 1st STORY |
| Class B | Closed | 6S | Feb 18, 2025 | REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CLOSE OUTLET HOLE AT NORTH WALL IN THE ENTIRE APARTMENT LOCATED AT APT 6S, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST |
| Class B | Closed | 6S | Feb 18, 2025 | REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOCK AT AT APARTMENT ENTRANCE DOOR IN THE ENTRANCE LOCATED AT APT 6S, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST |
| Class B | Closed | 6S | Dec 26, 2024 | REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6S, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 6S | Dec 26, 2024 | SECURE LOOSE MATTER · MAINTENANCE§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WASH BASIN IN THE BATHROOM LOCATED AT APT 6S, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class A | Closed | 6S | Dec 26, 2024 | RESET WATER CLOSET BOWL · SEWERS AND DRAINAGE§ 27-2026 ADM CODE RESET, SO AS TO SECURE A PROPER AND TIGHT CONNECTION, THE WATER CLOSET BOWL ... IN THE BATHROOM LOCATED AT APT 6S, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 6S | Dec 26, 2024 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6S, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class A | Closed | 6S | Dec 26, 2024 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT ALL WALLS IN THE BATHROOM LOCATED AT APT 6S, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 6S | Dec 26, 2024 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT ALL WALLS IN THE BATHROOM LOCATED AT APT 6S, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class A | Closed | 6S | Dec 26, 2024 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL AT BATHTUB BY METHOD OF REGLAZING IN THE BATHROOM LOCATED AT APT 6S, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class A | Closed | 6S | Dec 26, 2024 | REPAIR LEAKY FAUCETS · WATER SUPPLY§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 6S, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 6S | Dec 12, 2024 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6S, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 6S | Dec 12, 2024 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC WALL TILES NORTH SOUTH AND EAST WALL IN THE BATHROOM LOCATED AT APT 6S, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 6S | Dec 12, 2024 | SECURE LOOSE MATTER · MAINTENANCE§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WASH BASIN IN THE BATHROOM LOCATED AT APT 6S, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class A | Open | 6S | Dec 12, 2024 | RESET WATER CLOSET BOWL · SEWERS AND DRAINAGE§ 27-2026 ADM CODE RESET, SO AS TO SECURE A PROPER AND TIGHT CONNECTION, THE WATER CLOSET BOWL ... IN THE BATHROOM LOCATED AT APT 6S, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST |