| Class B | Open | — | May 20, 2026 | REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ASSEMBLIES AT NORTH 1 STAIR AT FIRE STAIRS, 3rd STORY |
| Class B | Open | — | May 20, 2026 | REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ASSEMBLIES SOUTH 1 AT FIRE STAIRS, 5th STORY |
| Class A | Open | — | May 20, 2026 | PROVIDE SHOE FOR DROP LADDER · FIRE EGRESS AND PROTECTION§ 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER SECURE WITH APPROPREATE BOLT AND NUTS AT 1st FIRE ESCAPE FROM NORTH AT EAST, 1st STORY |
| Class B | Open | — | May 20, 2026 | REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ASSEMBLIES NORTH 1 AT FIRE STAIRS, 5th STORY |
| Class C | Open | — | Mar 5, 2026 | PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM |
| Class C | OpenRENT IMPAIRING | 6H | Mar 5, 2026 | INADEQUATE HOT WATER · HEAT AND HOT WATER§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 6H, 6th STORY, 5th APARTMENT FROM SOUTH AT WEST |
| Class B | Open | 5H | Oct 21, 2025 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ...RUBBER GASKET AT REFRIDGERATOR DOOR IN THE KITCHEN LOCATED AT APT 5H, 5th STORY, 4th APARTMENT FROM SOUTH AT WEST |
| Class B | Open | 5H | Oct 21, 2025 | REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK ...AT WEST WALL WINDOW FRAME IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 5H, 5th STORY, 4th APARTMENT FROM SOUTH AT WEST |
| Class C | Open | 5H | Oct 21, 2025 | ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5H, 5th STORY, 4th APARTMENT FROM SOUTH AT WEST |
| Class B | Open | 6H | Apr 8, 2025 | REPAIR LEAKY FAUCETS · WATER SUPPLY§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASH BASIN IN THE BATHROOM LOCATED AT APT 6H, 6th STORY, 5th APARTMENT FROM SOUTH AT WEST |
| Class C | Open | 2H | Aug 23, 2024 | REMOVE EXCESSIVE STORAGE · EGRESS§ 27-2005, 2012 HMC & § 309 MDL: ABATE THE NUISANCE CONSISTING OF EXCESSIVE STORAGE OF MATERIAL HOUSEHOLD ARTICLES ETC. IN THE ENTIRE APARTMENT LOCATED AT APT 2H, 2nd STORY, 4th APARTMENT FROM SOUTH AT WEST |
| Class C | Open | 2H | Aug 16, 2024 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... CONSISTING OF APPROXIMATELY 18 SQUARE FEET AT CEILING AND WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 2H, 2nd STORY ORIGINAL VIOLATION 17010360 ISSUED 28-MAY-24 HAS BEEN UPGRADED TO CLASS C PER ADMINISTRATIVE CODE §27-2017.3a(5)(a) or (b). |
| Class B | Open | 2H | May 30, 2024 | NO SMOKE DETECTOR OR SMOKE DECTOR NOT OPERATIONAL · SMOKE DETECTING DEVICES§ 27-2045, 2046 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2H, 2nd STORY |
| Class B | Open | 2H | May 30, 2024 | REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2H, 2nd STORY, 4th APARTMENT FROM SOUTH AT WEST |
| Class C | Open | 2H | May 30, 2024 | ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2H, 2nd STORY |
| Class C | Open | 2H | May 30, 2024 | ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2H, 2nd STORY |
| Class B | Open | 2H | May 30, 2024 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... CONSISTING OF APPROXIMATELY 12 SQUARE FEET AT CEILING AND WEST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2H, 2nd STORY, 4th APARTMENT FROM SOUTH AT WEST |
| Class B | Open | 2H | May 30, 2024 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 2H, 2nd STORY |
| Class B | Open | 2H | May 30, 2024 | REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 2H, 2nd STORY |
| Class B | Open | 2H | May 30, 2024 | NO CO DETECTOR OR DETECTOR NOT OPERATIONAL · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2H, 2nd STORY |
| Class B | Open | 2H | May 30, 2024 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 2H, 2nd STORY, 4th APARTMENT FROM SOUTH AT WEST |
| Class B | Open | 2H | May 30, 2024 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... CONSISTING OF APPROXIMATELY 15 SQUARE FEET AT CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 2H, 2nd STORY, 4th APARTMENT FROM SOUTH AT WEST |
| Class I | Open | — | — | VACATED APARTMENT(S) · ORDER TO REPAIR/VACATE ORDER§ 27-2142 ADM CODE APTS HAVE BEEN VACATED BY THIS DEPARTMENT AND CANNOT BE REOCCUPIED UNTIL SO ORDERED AFTER PROOF OF COMPLIANCE FOR APTS WEST 3 CELLAR APT. LLB (VACATE #115031) |