| Class B | Closed | 8C | Jun 27, 2022 | REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 8C, 9th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 8C | Jun 27, 2022 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 8C, 9th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 3A | Jun 27, 2022 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT SOUTH WALL APPROX 12 SQ FT, AT WEST WALL APPROX 6 SQ FT IN THE 2nd ROOM FROM EAST LOCATED AT APT 3A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 10H | Jun 27, 2022 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 10H, 11th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 10H | Jun 27, 2022 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD BASE AT SINK CABINET IN THE KITCHEN LOCATED AT APT 10H, 11th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 3A | Jun 27, 2022 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT SOUTH WALL APPROX 12 SQ FT, AT WEST WALL APPROX 8 SQ FT IN THE 4th ROOM FROM EAST LOCATED AT APT 3A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Open | 8C | Jun 27, 2022 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 28 SQ FT AROUND THE WINDOW FRAME AT EAST WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 8C, 9th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Open | 8C | Jun 27, 2022 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING APPROX 5 SQ FT, AT EAST WALL APPROX 3 SQ FT, AT SOUTH WALL APRROX 2 SQ FT IN THE BATHROOM LOCATED AT APT 8C, 9th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Open | 10H | Jun 27, 2022 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT WEST WALL APPROX 15 SQ FT IN THE 4th ROOM FROM EAST LOCATED AT APT 10H, 11th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Open | 12C | Jun 27, 2022 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING APPROX 15 SQ FT IN THE PRIVATE HALLWAY LOCATED AT APT 12C, 13th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Open | 12C | Jun 27, 2022 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING APPROX 12 SQ FT, AT SOUTH WALL APPROX 2 SQ FT, AT WEST WALL APPROX 1 SQ FT, AT NORTH WALL APPROX 3 SQ FT, AT EAST WALL APPROX 2 SQ FT IN THE BATHROOM LOCATED AT APT 12C, 13th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Open | 3A | Jun 2, 2022 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX. 5 SQ. FT. AT WEST WALL, 10 SQ. FT. AT WEST WALL, 1 SQ. FT. AT SOUTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 3A | Jun 2, 2022 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX. 15 SQ. FT. AT SOTH WALL, 4 SQ. FT. AT NORTH WALL IN THE 5th ROOM FROM EAST LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 3A | Jun 2, 2022 | REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 3A | Jun 2, 2022 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | — | Jun 2, 2022 | PROVIDE · MAINTENANCE§ 27-2005 ADM CODE PROVIDE SECURITY IN THE EVENT OF A POWER OUTAGE BY MEAN OF AN ACCEPTABLE MECHANICAL HEAVY DUTY LOCK AND LATCH SET AT VESTIBULE DOOR , 1st STORY |
| Class B | Closed | 3A | Jun 2, 2022 | REPAIR LEAKY FAUCETS · WATER SUPPLY§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASHBASIN IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Open | 3A | Jun 2, 2022 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX. 10 SQ. FT. AT SOUTH WALL, 6 SQ. .FT. AT EAST WALL. IN THE 2nd BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 3A | Jun 2, 2022 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX. 16 SQ. FT AT SOUTH WALL, 1 SQ. FT. AT NORTH WALL, 12 SQ. FT. AT EAST WALL. IN THE FOYER LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 9M | Jun 1, 2022 | REPAIR LEAKY FAUCETS · WATER SUPPLY§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 9M, 9th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT NORTH |
| Class B | ClosedRENT IMPAIRING | 9M | Jun 1, 2022 | REMOVE OBSTRUCTIONS · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTELINE PIPE AT WASHBASIN IN THE BATHROOM LOCATED AT APT 9M, 9th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT NORTH |
| Class B | ClosedRENT IMPAIRING | 9M | Jun 1, 2022 | REMOVE OBSTRUCTIONS · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTELINE PIPE AT BATHTUB IN THE BATHROOM LOCATED AT APT 9M, 9th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT NORTH |
| Class B | Closed | 9M | Jun 1, 2022 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 9M, 9th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT NORTH |
| Class B | Closed | 3A | May 11, 2022 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 3A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 3C | Apr 28, 2022 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 3C | Apr 28, 2022 | ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF LOCKABLE SLIDE BOLT AT DOOR IN THE ENTRANCE LOCATED AT APT 3C, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 3C | Apr 28, 2022 | REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 1H | Apr 21, 2022 | REPAIR LEAKY FAUCETS · WATER SUPPLY§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 1H, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | PHG | Apr 18, 2022 | REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT PHG, 13th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 3A | Apr 18, 2022 | RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE SPRING BALANCE AT WINDOW LOWER SASH IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | PHG | Apr 18, 2022 | REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT PHG, 13th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 3A | Mar 28, 2022 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 3A | Mar 28, 2022 | REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 3A | Mar 28, 2022 | REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BASE CABINET DOORS AT NORTH WALL IN THE KITCHEN LOCATED AT APT 3A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 3A | Mar 28, 2022 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL WALLS IN THE 2nd BATHROOM FROM EAST LOCATED AT APT 3A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 3A | Mar 28, 2022 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... ( APPROX. 12 SQ. FT) AT SOUTH WALL, ( APPROX. 6 SQ. FT) AT CEILING IN THE 2nd BATHROOM FROM EAST LOCATED AT APT 3A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 3A | Mar 24, 2022 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE KITCHEN LOCATED AT APT 3A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 3A | Mar 24, 2022 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... ( APPROX. 12 SQ. FT) AT SOUTH WALL, ( APPROX. 8 SQ. FT) AT WEST WALL IN THE 4th ROOM FROM EAST AT SOUTH LOCATED AT APT 3A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 3A | Mar 24, 2022 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... ( APPROX. 12 SQ. FT) AT SOUTH WALL, ( APPROX. 6 SQ. FT) AT WEST WALL IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 3A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 3A | Mar 24, 2022 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... ( APPROX. 12 SQ. FT) AT SOUTH WALL, ( APPROX. 4 SQ. FT) AT EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 3A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 3A | Mar 24, 2022 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... ( APPROX. 12 SQ. FT) AT EAST WALL, ( APPROX. 8 SQ. FT) AT NORTH WALL, ( APPROX. 8 SQ. FT) AT CEILING IN THE FOYER LOCATED AT APT 3A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 3A | Mar 24, 2022 | REPAIR BROKEN, LOOSE CONNECTION · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASTELINE PIPE UNDER SINK IN THE KITCHEN LOCATED AT APT 3A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 3A | Mar 24, 2022 | REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE CLOSET DOORS IN THE PRIVATE HALLWAY LOCATED AT APT 3A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 3A | Mar 24, 2022 | REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOWER SASH WINDOW COUNTERBALANCE IN THE 4th ROOM FROM EAST AT NORTH LOCATED AT APT 3A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 3A | Mar 24, 2022 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE PRIVATE HALLWAY LOCATED AT APT 3A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 10H | Jan 24, 2022 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 15 SQ. FT. AT SOUTH WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 10H, 10th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH |
| Class B | Closed | 10H | Jan 24, 2022 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE SOUTH WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 10H, 10th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH |
| Class B | Closed | 10H | Jan 24, 2022 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX. 15 SQ. AT WEST WALL IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 10H, 10th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH |
| Class B | Closed | 7L | Jan 18, 2022 | REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 7L, 8th STORY, 11th APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 7L | Jan 18, 2022 | REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INOPERATIVE BELL/BUBUZZER/INTERCOM SYSTEM FROM BUILDING ENTRANCE TO THE FOYER LOCATED AT APT 7L, 8th STORY, 11th APARTMENT FROM SOUTH AT WEST |