| Class B | Closed | — | Oct 28, 2019 | REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF AIR CONDITIONER PROTRUDING MORE THAN 4 INCHES INTO THE PATH OF THE FIRE ESCAPE AT 2ND STORY BALCONY AT SOUTHCENTER STACK |
| Class B | Closed | — | Oct 28, 2019 | REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSEHOLD ITEMS AT 33RD AND 5TH STORY BALCONIES AT SOUTHEAST STACK |
| Class B | Closed | — | Nov 27, 2018 | REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF AIR CONDITIONER AT WINDOW IN THE 2ND STORY BALCONY 2ND STACK FROM NORTH AT BUILDING FRONT AT FIRE ESCAPE |
| Class B | Closed | — | Oct 24, 2018 | REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF FLOWER POTS AT 6TH STORY BALCONY ,STACK ON WEST EXTERIOR WALL |
| Class B | Closed | 1E | Sep 27, 2018 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 1E, 1st STORY, 3rd APARTMENT FROM NORTH AT EAST |
| Class B | Closed | 1E | Sep 27, 2018 | REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INOPERATIVE COUNTER BALANCE AT UPPER SASH WINDOW 3RD FROM NORTH AT EAST WALL. IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 1E, 1st STORY, 3rd APARTMENT FROM NORTH AT EAST |
| Class B | Closed | 1E | Sep 27, 2018 | REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BASE CABINET AT SINK IN THE KITCHEN LOCATED AT APT 1E, 1st STORY, 3rd APARTMENT FROM NORTH AT EAST |
| Class B | Closed | — | May 24, 2018 | REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSE HOLD ITEMS AT 6TH STORY BALCONY, 2ND STACK FROM WEST, BUILDING FRONT |
| Class B | Closed | — | Mar 27, 2018 | REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF FLOWER POTS AT 2 STY BALCONY OF FRONT FIRE ESCAPE |
| Class B | Closed | 1F | Feb 2, 2018 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT WEST WALL IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 1F, 3rd APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 1F | Feb 2, 2018 | REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 1F, 3rd APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 1F | Feb 2, 2018 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT SOUTH WALL IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 1F, 3rd APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 1F | Feb 2, 2018 | MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ... IN THE ENTRANCE LOCATED AT APT 1F, 3rd APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 1F | Feb 2, 2018 | REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 1F, 3rd APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 1F | Feb 2, 2018 | REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 1F, 3rd APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | — | Feb 2, 2018 | MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS AT WEST SECTION, NORTH WALL , USE TO ACCESS LAUNDRY ROOM , BASEMENT STORY, AT PUBLIC HALL |
| Class B | Closed | — | Feb 2, 2018 | SECURE LOOSE MATTER · MAINTENANCE§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE METAL COVER FOR BELL BUZZER ,AT VESTIBULE, WEST WALL , AT PUBLIC HALL |
| Class B | ClosedRENT IMPAIRING | 1F | Feb 2, 2018 | REMOVE ILLEGAL FASTENING · EGRESS§ 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING KEY OPERATED LOCK AT DOOR KNOB ON THE INTERIOR IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 1F, 3rd APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | — | Feb 2, 2018 | REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSEHOLD ITEMS AT , BALCONY , SOUTHEAST SECTION, BUILDING FRONT, AT FIRE ESCAPE, 4th STORY |
| Class B | Closed | 1C | Dec 12, 2016 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM NORTH AT EAST |
| Class B | Closed | 1C | Dec 12, 2016 | NO CO DETECTOR OR DETECTOR NOT OPERATIONAL · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM NORTH AT EAST |
| Class B | Closed | 2K | Jul 7, 2015 | RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIREDSECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE DOOR IN THE BATHROOM LOCATED AT APT 2K, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Class B | ClosedRENT IMPAIRING | 2K | Jul 7, 2015 | REPAIR FLUSHING APPARATUS OF WATER CLOSET · SEWERS AND DRAINAGESECTION 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET .. IN THE BATHROOM LOCATED AT APT 2K, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 2K | Jul 7, 2015 | PROVIDE SUPPLY OF ELECTRICTY TO FIXTURES · ARTIFICIAL LIGHTINGSECTION 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES .. IN THE BATHROOM LOCATED AT APT 2K, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 2K | Jul 7, 2015 | REPAIR LEAKY FAUCETS · WATER SUPPLYSECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS .. IN THE BATHROOM LOCATED AT APT 2K, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 2K | Jul 7, 2015 | REPAIR · MAINTENANCESECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE VENT COVER IN THE BATHROOM LOCATED AT APT 2K, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 2J | Jan 8, 2014 | NO CO DETECTOR OR DETECTOR NOT OPERATIONAL · CARBON MONOXIDE DETECTING DEVICESSECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2J, 2nd STORY, 6th APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 2J | Jan 8, 2014 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICESSECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2J, 2nd STORY, 6th APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 2G | Dec 17, 2013 | NO CO DETECTOR OR DETECTOR NOT OPERATIONAL · CARBON MONOXIDE DETECTING DEVICESSECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. LOCATED AT APT 2G, 2nd STORY, APARTMENT AT SOUTH |
| Class B | Closed | 2G | Dec 17, 2013 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICESSECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR (DEFECTIVE) LOCATED AT APT 2G, 2nd STORY, APARTMENT AT SOUTH |