| Class B | Closed | 4D | Oct 11, 2016 | REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). ....MISSING LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM NORTH AT EAST |
| Class A | Closed | — | Nov 9, 2015 | REPLACE · MAINTENANCE§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRICAL OUTLET SAFETY COVER/ CAPS PLATES AT PUBLIC HALL, 1st STORY |
| Class A | Closed | 5H | Nov 9, 2015 | PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 1st ROOM FROM EAST AT SOUTH, THE FOYER , THE BATHROOM , THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 5H, 5th STORY, 5th APARTMENT FROM NORTH AT EAST |
| Class B | Closed | 5H | Nov 9, 2015 | REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERATIVE LOCATED AT APT 5H, 5th STORY, 5th APARTMENT FROM NORTH AT EAST |
| Class B | Closed | 5H | Nov 9, 2015 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERATIVE LOCATED AT APT 5H, 5th STORY, 5th APARTMENT FROM NORTH AT EAST |
| Class B | Closed | 5H | Nov 9, 2015 | REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK OVER CEILING CEILING IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 5H, 5th STORY, 5th APARTMENT FROM NORTH AT EAST |
| Class A | Closed | — | Sep 17, 2015 | POST HOUSING INFORMATION GUIDE NOTICE · POSTING/SIGNAGE§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY |
| Class A | Closed | — | Apr 1, 2015 | POST HOUSING INFORMATION GUIDE NOTICE · POSTING/SIGNAGESECTION 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCY?S HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY |
| Class C | Closed | — | Apr 1, 2015 | REPAIR · MAINTENANCESECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCKING DEVIICE AT ENTRNACE DOOR TO BUILDING AT PUBLIC HALL, 1st STORY |
| Class A | Closed | — | Mar 19, 2015 | POST HOUSING INFORMATION GUIDE NOTICE · POSTING/SIGNAGESECTION 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCY?S HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. |
| Class B | Closed | — | Sep 9, 2014 | RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIREDSECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS AT THE VESTIBULE DOOR LEADING TO THE 1ST STORY PUBLIC HALL. |
| Class B | Closed | 5K | Aug 8, 2014 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANINGSECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT WEST WALL / 1 SQUARE FEET / IN THE BATHROOM LOCATED AT APT 5K, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 5K | Aug 8, 2014 | REPAIR PLASTER · MAINTENANCESECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE KITCHEN LOCATED AT APT 5K, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Class C | Closed | 5K | Aug 8, 2014 | REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLYSECTION 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 5K, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 5K | Aug 8, 2014 | REMOVE BARS OR GATES FROM FIRE ESCAPE WINDOW · EGRESSSECTION 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE .. IN THE ENTIRE APARTMENT LOCATED AT APT 5K, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 5K | Aug 8, 2014 | REPAIR BROKEN, LOOSE CONNECTION · SEWERS AND DRAINAGESECTION 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT DRAIN PIPE TO SINK IN THE KITCHEN LOCATED AT APT 5K, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 3M | May 29, 2014 | ABATE THE NUISANCE OF BEDBUGS · EXTERMINATION & RODENT ERADICATION§ 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF BEDBUGS IN THE ENTIRE APARTMENT LOCATED AT APT 3M, 3rd STORY, 3rd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 3M | May 29, 2014 | REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 3M, 3rd STORY, 3rd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 3M | May 29, 2014 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 3M, 3rd STORY, 3rd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 3M | May 15, 2014 | ABATE THE NUISANCE OF BEDBUGS · EXTERMINATION & RODENT ERADICATION§ 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF BEDBUGS LOCATED AT APT 3M, 3rd STORY, 3rd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 3M | May 15, 2014 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR WHICH IS DEFECTIVE LOCATED AT APT 3M, 3rd STORY, 3rd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 3M | May 15, 2014 | REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). WHICH IS DEFECTIVE LOCATED AT APT 3M, 3rd STORY, 3rd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 3M | May 15, 2014 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 3M, 3rd STORY, 3rd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 3M | May 15, 2014 | REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE BATHROOM LOCATED AT APT 3M, 3rd STORY, 3rd APARTMENT FROM SOUTH AT WEST |
| Class C | Closed | 3M | May 15, 2014 | INSTALL/REPLACE/REPAIR WINDOW GUARDS (APT) · WINDOW GUARDSSECTION 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 4; WG TO REPLACE = 0; WG TO REPAIR = 1; LOCATED AT APT 3M, 3rd STORY, 3rd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 4G | Feb 18, 2014 | REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT SOUTH WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 4G, 4th STORY, 4th APARTMENT FROM NORTH AT EAST |
| Class B | Closed | 4G | Feb 18, 2014 | REPLACE · MAINTENANCE§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING COVER FOR ELECTRICAL OUTLET AT NORTH WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 4G, 4th STORY, 4th APARTMENT FROM NORTH AT EAST |
| Class B | Closed | 4G | Feb 18, 2014 | REPLACE · MAINTENANCE§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING COVERS FOR ELECTRICAL OUTLET AT NORTH AND EAST WALLS (TOTAL OF TWO) IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 4G, 4th STORY, 4th APARTMENT FROM NORTH AT EAST |
| Class B | Closed | 4G | Feb 18, 2014 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... 20 SQUARE FEET AT EAST WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 4G, 4th STORY, 4th APARTMENT FROM NORTH AT EAST |
| Class B | Closed | 4G | Feb 18, 2014 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4G, 4th STORY, 4th APARTMENT FROM NORTH AT EAST |
| Class B | Closed | 4G | Feb 18, 2014 | NO CO DETECTOR OR DETECTOR NOT OPERATIONAL · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 4G, 4th STORY, 4th APARTMENT FROM NORTH AT EAST |
| Class C | ClosedRENT IMPAIRING | — | Feb 18, 2014 | F/E ADJUST THE DROP LADDER · EGRESSSECTION 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS AT SOUTH EAST FIRE ESCAPE AT BUILDING FRONT |
| Class C | Closed | 4G | Feb 18, 2014 | INSTALL/REPLACE/REPAIR WINDOW GUARDS (APT) · WINDOW GUARDS§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 4; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 4G, 4th STORY, 4th APARTMENT FROM NORTH AT EAST |
| Class B | Closed | 4G | Feb 18, 2014 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... APP. 10 SQ. FT AT NORTH WINDOWFRAME IN THE KITCHEN LOCATED AT APT 4G, 4th STORY, 4th APARTMENT FROM NORTH AT EAST |
| Class B | ClosedRENT IMPAIRING | — | Feb 18, 2014 | F/E ADJUST THE DROP LADDER · EGRESSSECTION 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS DROP LADDER OUT OF GRAVITY HOOK AT BUILDING FRONT SOUTH 1 FIRE ESCAPE |
| Class C | Closed | 6L | Feb 18, 2014 | LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st RADIATOR FROM SOUTH AT WEST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 6L, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class C | Closed | 4G | Feb 18, 2014 | INSTALL/REPLACE/REPAIR WINDOW GUARDS (APT) · WINDOW GUARDS§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 5; WG TO REPLACE = 0; WG TO REPAIR = 0; LOCATED AT APT 4G, 4th STORY, 4th APARTMENT FROM NORTH AT EAST |
| Class B | Closed | 4G | Feb 18, 2014 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERABLE LOCATED AT APT 4G, 4th STORY, 4th APARTMENT FROM NORTH AT EAST |
| Class B | Closed | 4G | Feb 18, 2014 | REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERABLE LOCATED AT APT 4G, 4th STORY, 4th APARTMENT FROM NORTH AT EAST |
| Class A | Closed | 4G | Feb 18, 2014 | PAINT · PAINTINGSECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 1st ROOM FROM NORTH, THE BATHROOM , THE KITCHEN , THE FOYER , THE PRIVATE HALLWAY , THE 3rd ROOM FROM NORTH, THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 4G, 4th STORY, 4th APARTMENT FROM NORTH AT EAST |
| Class C | Closed | 6G | Dec 12, 2013 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 6G, 6th STORY |
| Class C | ClosedRENT IMPAIRING | 6G | Dec 12, 2013 | LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 6G, 6th STORY |
| Class C | Closed | 6G | Dec 12, 2013 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 6G, 6th STORY |
| Class C | ClosedRENT IMPAIRING | 6G | Dec 12, 2013 | LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 6G, 6th STORY |
| Class B | Closed | 6G | Dec 12, 2013 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 6G, 6th STORY |
| Class B | Closed | 6G | Dec 12, 2013 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT WEST WALL,APPROX. 20 SQUARE FEET IN THE BATHROOM LOCATED AT APT 6G, 6th STORY |
| Class C | Closed | — | Sep 27, 2013 | ABATE THE NUISANCE · MAINTENANCESECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF AN ACCEPTABLE, HEAVY-DUTY LOCK-AND-LATCH SET ON DOOR AT ENTRANCE TO THE BUILDING AT PUBLIC HALL |
| Class C | Closed | — | Sep 27, 2013 | REMOVE ACCUMULATION OR RUBBISH · CLEANINGSECTION 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE FLOOR AT THE NORTH OF THE BUILDING OF APPROXIMATELY 5 CUBIC YARDS AT FIRE PASSAGE WAY |
| Class A | Closed | — | Sep 27, 2013 | PROVIDE SHOE FOR DROP LADDER · FIRE EGRESS AND PROTECTIONSECTION 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER ON 2ND STACK FROM NORTH ON THE WEST SIDE OF THE BUILDING |
| Class C | ClosedRENT IMPAIRING | — | Sep 27, 2013 | REMOVE ILLEGAL FASTENING · EGRESSSECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF A PADLOCK ON THE REAR GATE AT THE NORTH OF THE BUILDING AT FIRE PASSAGE WAY |