| Class B | Closed | — | Oct 31, 2018 | REPAIR/ABATE UNSAFE WIRES · ARTIFICIAL LIGHTING§ 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT, METAL CONDUIT, NORTH WALL, NORTHEAST SECTION, AT PUBLIC HALL, 1st STORY |
| Class B | Closed | — | Oct 31, 2018 | SECURE LOOSE MATTER · MAINTENANCE§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE METAL CONDUIT, NORTH WALL, NORTHEAST SECTION, AT PUBLIC HALL, 1st STORY |
| Class B | Closed | C2 | Oct 31, 2018 | REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERATIVE IN THE ENTIRE APARTMENT LOCATED AT APT C2, 1st STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''NE'' |
| Class B | Closed | — | Oct 30, 2018 | REPLACE · MAINTENANCE§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING HANDRAIL, AT PUBLIC HALL STAIRS, 1st STORY, SECTION ''NORTHWEST'' |
| Class B | Closed | A11 | Oct 30, 2018 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT A11, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Class B | Closed | A11 | Oct 30, 2018 | REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT A11, 3rd STORY, APARTMENT AT EAST |
| Class B | Closed | C2 | Oct 30, 2018 | REPAIR/ABATE UNSAFE WIRES · ARTIFICIAL LIGHTING§ 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF BX-CABLE CABLE WITH EXPOSED ELECTRICAL WIRES AT, ARCHWAY ENTRANCE TO BUILDING, EAST WALL, COURT YARD LOCATED AT APT C2, 1st STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''NE'' |
| Class B | Closed | — | Oct 29, 2018 | REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCKING DEVICE AT ENTRANCE DOOR TO BUILDING, 1ST STORY, NORTHEAST SECTION, , 2nd STORY |
| Class B | Closed | — | Oct 29, 2018 | REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCKING DEVICE AT ENTRANCE DOOR TO BUILDING, 1ST STORY, NORTHWEST, , 1st STORY |
| Class B | Closed | 12C | Oct 26, 2018 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WEST WALL, CEILING IN THE BATHROOM LOCATED AT APT 12C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''NE'' |
| Class B | ClosedRENT IMPAIRING | 12C | Oct 26, 2018 | LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 12C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''NE'' |
| Class B | Closed | C12 | Oct 26, 2018 | ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATION§ 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT C12, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''NE'' |
| Class B | Closed | 12C | Oct 26, 2018 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL, EAST WALL, CEILING IN THE KITCHEN LOCATED AT APT 12C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''NE'' |
| Class B | Closed | C12 | Oct 26, 2018 | ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATION§ 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT C12, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''NE'' |
| Class B | Closed | 12C | Oct 26, 2018 | ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATION§ 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 12C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''NE'' |
| Class B | Closed | C12 | Oct 26, 2018 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERATIVE IN THE ENTIRE APARTMENT LOCATED AT APT C12, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''NE'' |
| Class B | Closed | C12 | Oct 26, 2018 | REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERATIVE IN THE ENTIRE APARTMENT LOCATED AT APT C12, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''NE'' |
| Class B | Closed | C12 | Oct 26, 2018 | REMOVE BARS OR GATES FROM FIRE ESCAPE WINDOW · EGRESS§ 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE AT NORTH WALL IN THE KITCHEN LOCATED AT APT C12, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''NE'' |
| Class B | Closed | 12C | Oct 26, 2018 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WEST WALL, NORTH WALL IN THE FOYER LOCATED AT APT 12C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''NE'' |
| Class B | Closed | 12C | Oct 26, 2018 | REMOVE BARS OR GATES FROM FIRE ESCAPE WINDOW · EGRESS§ 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE AT NORTH WALL IN THE KITCHEN LOCATED AT APT 12C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''NE'' |
| Class B | Closed | 12C | Oct 26, 2018 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL, CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 12C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''NE'' |
| Class B | Closed | 12C | Oct 26, 2018 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 12C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''NE'' |
| Class B | ClosedRENT IMPAIRING | 12C | Oct 26, 2018 | LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 12C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''NE'' |
| Class B | Closed | C2 | Oct 26, 2018 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCATED AT APT C2, 1st STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''NE'' |
| Class B | Closed | 2B | Oct 24, 2018 | ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF ELECTRICAL EXTENTION WIRE WITH ATTACHED OUTLET AT THE WEST WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 2B, 2nd STORY, APARTMENT AT NORTH , SECTION ''B'', AT SOUTHEAST |
| Class B | Closed | 2B | Oct 24, 2018 | ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXCESSIVE ELECTRICAL EXTENTION WIRES RUNNING THROUGHOUT IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY, APARTMENT AT NORTH , SECTION ''B'', AT SOUTHEAST |
| Class B | Closed | 2B | Oct 24, 2018 | REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT THE SOUTH WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 2B, 2nd STORY, APARTMENT AT NORTH , SECTION ''B'', AT SOUTHEAST |
| Class B | ClosedRENT IMPAIRING | A12 | Oct 24, 2018 | MAKE GAS TIGHT · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REPAIR BY CLOSING SO AS TO BE GAS TIGHT ALL OPENINGS IN THE WASTE LINE OF THE SINK IN THE KITCHEN LOCATED AT APT A12, 4th STORY, APARTMENT AT NORTH , SECTION ''A'', AT SOUTHWEST |
| Class B | Closed | 2B | Oct 24, 2018 | PROVIDE SUPPLY OF ELECTRICTY TO FIXTURES · ARTIFICIAL LIGHTING§ 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES .. IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 2B, 2nd STORY, APARTMENT AT NORTH , SECTION ''B'', AT SOUTHEAST |
| Class B | Closed | A12 | Oct 24, 2018 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR : DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT A12, 4th STORY, APARTMENT AT NORTH , SECTION ''A'', AT SOUTHWEST |
| Class B | Closed | C3 | Oct 24, 2018 | REPLACE · MAINTENANCE§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING WASTE LINE OF THE WASHBASIN IN THE BATHROOM LOCATED AT APT C3, 1st STORY, APARTMENT AT NORTH |
| Class B | Closed | A12 | Oct 24, 2018 | RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE BASE CABINET OF THE SINK IN THE KITCHEN LOCATED AT APT A12, 4th STORY, APARTMENT AT NORTH , SECTION ''A'', AT SOUTHWEST |
| Class B | Closed | A12 | Oct 24, 2018 | REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). : MISSING IN THE ENTIRE APARTMENT LOCATED AT APT A12, 4th STORY, APARTMENT AT NORTH , SECTION ''A'', AT SOUTHWEST |
| Class B | Closed | C10 | Oct 24, 2018 | MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .. IN THE ENTRANCE LOCATED AT APT C10, 4th STORY, SECTION ''C'', AT NORTHEAST |
| Class B | Closed | 2B | Oct 24, 2018 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND WALLS IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, APARTMENT AT NORTH , SECTION ''B'', AT SOUTHEAST |
| Class B | Closed | 2B | Oct 24, 2018 | PROVIDE SUPPLY OF ELECTRICTY TO FIXTURES · ARTIFICIAL LIGHTING§ 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES .. IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 2B, 2nd STORY, APARTMENT AT NORTH , SECTION ''B'', AT SOUTHEAST |
| Class B | Closed | 2B | Oct 24, 2018 | REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, APARTMENT AT NORTH , SECTION ''B'', AT SOUTHEAST |
| Class B | Closed | A13 | Oct 23, 2018 | REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). : DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT A13, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''A'', AT SOUTHWEST |
| Class B | Closed | D3 | Oct 23, 2018 | REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE KITCHEN LOCATED AT APT D3, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''D'', AT NORTHWEST |
| Class B | Closed | A13 | Oct 23, 2018 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR : DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT A13, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''A'', AT SOUTHWEST |
| Class B | Closed | D3 | Oct 23, 2018 | REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE PRIVATE HALLWAY LOCATED AT APT D3, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''D'', AT NORTHWEST |
| Class B | Closed | D3 | Oct 23, 2018 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE KITCHEN LOCATED AT APT D3, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''D'', AT NORTHWEST |
| Class B | Closed | A13 | Oct 23, 2018 | MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .. IN THE ENTRANCE LOCATED AT APT A13, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''A'', AT SOUTHWEST |
| Class B | Closed | B11 | Oct 22, 2018 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT B11, 4th STORY, APARTMENT AT NORTH , SECTION AT EAST |
| Class B | Closed | B11 | Oct 22, 2018 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE KITCHEN LOCATED AT APT B11, 4th STORY, APARTMENT AT NORTH , SECTION AT EAST |
| Class B | Closed | B11 | Oct 22, 2018 | MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT THE ENTRANCE LOCATED AT APT B11, 4th STORY, APARTMENT AT NORTH , SECTION AT EAST |
| Class B | Closed | B11 | Oct 22, 2018 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE PRIVATE HALLWAY LOCATED AT APT B11, 4th STORY, APARTMENT AT NORTH , SECTION AT EAST |
| Class B | Closed | B6 | Oct 15, 2018 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR UNDER SINK IN THE KITCHEN LOCATED AT APT B6, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''B'' |
| Class B | ClosedRENT IMPAIRING | B6 | Oct 15, 2018 | REMOVE OBSTRUCTIONS · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN BATHTUB IN THE BATHROOM LOCATED AT APT B6, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''B'' |
| Class B | Closed | B6 | Oct 15, 2018 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT B6, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''B'' |