| Class B | OpenRENT IMPAIRING | 4N | Jun 12, 2023 | LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 4N, 4th STORY, 1st APARTMENT FROM NORTH AT EAST |
| Class B | Open | 4N | Jun 12, 2023 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 4N, 4th STORY, 1st APARTMENT FROM NORTH AT EAST |
| Class B | Open | 1F | Jun 12, 2023 | REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Open | 1H | Jun 12, 2023 | REPAIR LEAKY FAUCETS · WATER SUPPLY§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATH TUB IN THE BATHROOM LOCATED AT APT 1H, 1st STORY, 3rd APARTMENT FROM NORTH AT EAST |
| Class B | Open | 1H | Jun 12, 2023 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT FLOOR IN THE BATHROOM LOCATED AT APT 1H, 1st STORY, 3rd APARTMENT FROM NORTH AT EAST |
| Class B | Open | 1B | Jun 8, 2023 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ROTTED WOOD SINK BASE CABINET IN THE KITCHEN LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Class B | Open | 4L | Jun 8, 2023 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Class B | Open | 4L | Jun 8, 2023 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Class B | Open | 1B | Jun 8, 2023 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL TILES AT FLOOR IN THE KITCHEN LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Class B | OpenRENT IMPAIRING | 4L | Jun 8, 2023 | LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Class B | Open | 1H | Jun 6, 2023 | REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 1H, 1st STORY, 3rd APARTMENT FROM NORTH AT EAST |
| Class B | Open | — | Feb 24, 2023 | REPLACE · MAINTENANCE§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING DOOR AT BUILDING ENTRANCE |
| Class B | OpenRENT IMPAIRING | — | Feb 10, 2023 | REMOVE ENCUMBRANCES · EGRESS§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF TWO SHOPING CART AT INTERMEDIAT LANDING OF BULKHEAD STAIRS AT PUBLIC HALL, 4th STORY, SECTION AT NORTH |
| Class B | Open | 1G | Oct 31, 2022 | REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE KITCHEN LOCATED AT APT 1G, 1st STORY, 2nd APARTMENT FROM NORTH AT EAST |
| Class B | Open | — | Oct 3, 2022 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT VESTIBULE AT PUBLIC HALL, 1st STORY |
| Class B | Open | — | Oct 3, 2022 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 1st STORY |
| Class B | Open | — | Jul 28, 2022 | REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF AIR CONDITIONER UNIT PROTRUDING MORE THAN 4 INCHES FROM WINDOW SILL AT THE BALCONY, WEST STACK AT WEST EXITEROR WALL AT FIRE ESCAPE, 4th STORY |
| Class B | Open | 1F | Mar 31, 2022 | REPAIR BROKEN, LOOSE CONNECTION · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WAST LINE AT WASH BASIN IN THE BATHROOM LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''east'' |
| Class B | Open | 1F | Mar 31, 2022 | RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE REFRIGERATOR RUBBER DOOR GASKET IN THE KITCHEN LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''east'' |
| Class B | Open | 1F | Mar 31, 2022 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''east'' |
| Class B | Open | — | Mar 31, 2022 | REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF AIR CONDITIONER UNIT PROTRUDING MORE THAN 4 INCHES AT THE BALCONY, SOUTH WEST STACK BUILDING FRONT AT FIRE ESCAPE, 4th STORY |
| Class B | Open | — | Mar 11, 2022 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT SOUTH WALL AT PUBLIC HALL, 2nd STORY, SECTION ''EAST'' |
| Class B | OpenRENT IMPAIRING | — | Mar 11, 2022 | LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING AT PUBLIC HALL, 4th STORY, SECTION ''EAST'' |
| Class B | Open | — | Mar 11, 2022 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 4th STORY, SECTION ''EAST'' |
| Class B | OpenRENT IMPAIRING | — | Mar 11, 2022 | REMOVE ENCUMBRANCES · EGRESS§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT PUBLIC HALL, 4th STORY, SECTION ''WEST'' |
| Class B | Open | 1G | Mar 9, 2022 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1G, 1st STORY, 3rd APARTMENT FROM NORTH AT EAST |
| Class B | Open | 4F | Mar 9, 2022 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT WEST WALL (12 SQ. FT. ) IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Open | 4F | Mar 9, 2022 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Open | 1G | Mar 9, 2022 | REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1G, 1st STORY, 3rd APARTMENT FROM NORTH AT EAST |
| Class B | OpenRENT IMPAIRING | 4F | Mar 9, 2022 | LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Open | 4F | Mar 9, 2022 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | OpenRENT IMPAIRING | 4F | Mar 9, 2022 | LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Open | 4L | Dec 14, 2021 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING, APPROXIMATELY 2 SQUARE FT IN THE KITCHEN LOCATED AT APT 4L, 1st STORY, 1st APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 14495379 ISSUED 07-AUG-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| Class B | Open | 4L | Nov 30, 2021 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 2 SQUARE FEET AT CEILING IN THE KITCHEN LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 14466712 ISSUED 24-JUL-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| Class B | Open | 1C | Nov 5, 2021 | REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL/BUZZ INTERCOM SYSTEM FROM BUILDING VESTIBULE TO FOYER LOCATED AT APT 1C, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT WEST |
| Class B | Open | — | Oct 21, 2021 | REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF AIR CONDITIONING UNIT PROTRUDING BEYOND WINDOW SILL AT 3RD STORY BALCONY, WEST STACK, BUILDING FRONT, MORE THAN 4 INCHES INTO THE PATH AT FIRE ESCAPE |
| Class B | Open | 4L | Aug 16, 2021 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE KITCHEN LOCATED AT APT 4L, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Class B | Open | 4L | Aug 16, 2021 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 4L, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Class B | Open | 4L | Aug 16, 2021 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD TRIM ON ALL SIDES AT WINDOW RECESS IN THE 1st ROOM FROM EAST LOCATED AT APT 4L, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Class B | Open | — | Aug 12, 2021 | REMOVE ACCUMULATION OR RUBBISH · CLEANING§ 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE COURT AT BUILDING FRONT |
| Class B | Open | 4L | Aug 9, 2021 | REPAIR BROKEN, LOOSE CONNECTION · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASTE LINE UNDER SINK IN THE KITCHEN LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Class B | Open | — | Aug 9, 2021 | PROVIDE SUPPLY OF ELECTRICTY TO FIXTURES · ARTIFICIAL LIGHTING§ 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING AT PUBLIC HALL, 4th STORY |
| Class B | Open | 4L | Aug 2, 2021 | REPAIR BROKEN, LOOSE CONNECTION · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASTE LINE AT SINK IN THE KITCHEN LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EAST |
| Class B | Open | 4L | Aug 2, 2021 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EAST |
| Class B | Open | 4L | Aug 2, 2021 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EAST |
| Class B | Open | 4L | Aug 2, 2021 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EAST |
| Class B | Open | 4L | Aug 2, 2021 | REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT EAST WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EAST |
| Class B | Open | 4L | Jul 29, 2021 | REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EAST |
| Class B | Open | 1F | Jul 27, 2021 | REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 1F | Jul 27, 2021 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... CEILING 8 SQUARE FEET, EAST WALL 7 SQUARE FEET IN THE 2nd ROOM FROM EAST LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |