| Class C | Open | 314 | Dec 8, 2025 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT 314, 3rd STORY, 3rd APARTMENT FROM SOUTH AT WEST |
| Class B | Open | 314 | Dec 8, 2025 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 314, 3rd STORY, 3rd APARTMENT FROM SOUTH AT WEST |
| Class B | Open | 314 | Dec 8, 2025 | REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 314, 3rd STORY, 3rd APARTMENT FROM SOUTH AT WEST |
| Class C | OpenRENT IMPAIRING | 314 | Dec 8, 2025 | INADEQUATE COLD WATER · WATER SUPPLY§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT BATHROOM AND KITCHEN IN THE ENTIRE APARTMENT LOCATED AT APT 314, 3rd STORY, 3rd APARTMENT FROM SOUTH AT WEST |
| Class C | Open | 314 | Dec 8, 2025 | ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF UNCAPPED STEAM RADIATOR VALVE IN THE 3rd ROOM FROM EAST LOCATED AT APT 314, 3rd STORY, 3rd APARTMENT FROM SOUTH AT WEST |
| Class B | Open | 314 | Dec 8, 2025 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 314, 3rd STORY, 3rd APARTMENT FROM SOUTH AT WEST |
| Class B | Open | 113 | Dec 4, 2025 | REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 113, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class C | Closed | — | Dec 4, 2025 | MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR AT DOUBLE FIRE DOOR 2ND FROM NORTH AT PUBLIC HALL, 3rd STORY |
| Class B | Closed | 113 | Dec 4, 2025 | REMOVE BARS OR GATES FROM NON FIRE ESCAPE WINDOW · EGRESS§ 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM AT LEAST 1 WINDOW OR PROVIDE APPROVED TYPE GATE , IN THE ENTIRE APARTMENT LOCATED AT APT 113, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Open | 113 | Dec 4, 2025 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 113, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class B | Closed | 605 | Dec 3, 2025 | REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 605, 6th STORY, 3rd APARTMENT FROM NORTH AT EAST |
| Class B | Closed | 605 | Dec 3, 2025 | REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 605, 6th STORY, 3rd APARTMENT FROM NORTH AT EAST |
| Class B | ClosedRENT IMPAIRING | — | Nov 20, 2025 | REMOVE ENCUMBRANCES · EGRESS§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF BICYCLES AND SCOOTERS AT PUBLIC HALL, 1st STORY |
| Class C | Open | 113 | Nov 17, 2025 | ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 113, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class C | Closed | 113 | Nov 12, 2025 | ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 113, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class C | Open | 113 | Nov 5, 2025 | ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 113, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class C | Open | 113 | Nov 5, 2025 | ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 113, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class C | Closed | 401 | Nov 5, 2025 | MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 401, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH |
| Class A | Open | 401 | Nov 5, 2025 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 401, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH |
| Class A | Closed | — | Nov 5, 2025 | REPLACE · MAINTENANCE§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SAFETY COVERS FOR ELECTRICAL OUTLETS AT WEST AND SOUTH WALLS AT PUBLIC HALL, 1st STORY |
| Class C | Closed | — | Nov 5, 2025 | MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE FIRE DOOR, 1ST FROM NORTH AT PUBLIC HALL, 4th STORY |
| Class B | ClosedRENT IMPAIRING | — | Oct 28, 2025 | REMOVE ENCUMBRANCES · EGRESS§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSE HOLD ITEMS UNDER STAIR CASE AT PUBLIC HALL, 1st STORY |
| Class A | Open | — | Oct 28, 2025 | PAINT METAL · PAINTING§ 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT FIRE ESCAPE SOUTH AND SOUTH STACK AT WEST YARD |
| Class B | ClosedRENT IMPAIRING | — | Oct 28, 2025 | REMOVE ENCUMBRANCES · EGRESS§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF BICYCLES AT PUBLIC HALL, 4th STORY |
| Class B | ClosedRENT IMPAIRING | — | Oct 28, 2025 | REMOVE ENCUMBRANCES · EGRESS§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF BICYCLES AT PUBLIC HALL, 3rd STORY |
| Class A | Open | — | Oct 28, 2025 | PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT BULKHEAD AT STAIRS (Y) |
| Class B | Closed | — | Oct 28, 2025 | REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE-RETARDANT MATERIAL AT CEILING AT BULKHEAD AT STAIRS (Y) |
| Class B | OpenRENT IMPAIRING | 609 | Oct 1, 2025 | LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE BATHROOM LOCATED AT APT 609, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH |
| Class B | OpenRENT IMPAIRING | 609 | Oct 1, 2025 | LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE KITCHEN LOCATED AT APT 609, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH |
| Class B | Open | 609 | Oct 1, 2025 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 609, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH |
| Class B | Open | 609 | Oct 1, 2025 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE BATHROOM LOCATED AT APT 609, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH |
| Class B | Closed | 212 | Oct 1, 2025 | TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQ.FT AT CEILING AND WEST WALL IN THE BATHROOM LOCATED AT APT 212, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | OpenRENT IMPAIRING | 609 | Oct 1, 2025 | LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 609, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH |
| Class B | Closed | 212 | Oct 1, 2025 | REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GLASS PANE AT LOWER WINDOW SASH, NO CUT HAZARD, 2ND WINDOW FROM EAST AT SOUTH IN THE 4th ROOM FROM NORTH LOCATED AT APT 212, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Open | 609 | Oct 1, 2025 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL IN THE KITCHEN LOCATED AT APT 609, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH |
| Class B | Closed | 212 | Sep 29, 2025 | REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 212, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 212 | Sep 29, 2025 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WEST WALL IN THE BATHROOM LOCATED AT APT 212, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class B | Closed | 212 | Sep 29, 2025 | REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INTERCOM SYSTEM FROM THE BUILDING ENTRANCE TO EAST WALL IN THE FOYER LOCATED AT APT 212, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Class C | Closed | 113 | Sep 22, 2025 | MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES ON DOOR IN THE ENTRANCE LOCATED AT APT 113, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Class C | Open | 409 | Sep 12, 2025 | CORRECT THE LEAD-BASED PAINT TESTED INCONCLUSIVE OR POSTIVE FOR METAL/CERAMIC SUBSTRATE · LEAD-BASED PAINT§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT 0.5MG/CM2 AND IS PRESUMED LEAD PAINT AS SET FORTH IN (28 RCNY §11-07(b)) AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE-USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(b)(2) 1st CLOSET FROM WEST AT NORTH WALL DOOR, 1st CLOSET FROM WEST AT NORTH WALL DOOR FRAME, 1st CLOSET FROM EAST AT SOUTH WALL DOOR IN THE 2nd PRIVATE HALLWAY FROM EAST LOCATED AT APT 409, 4th STORY, 7th APARTMENT FROM NORTH AT EAST |
| Class C | Open | 409 | Sep 12, 2025 | CORRECT THE LEAD-BASED PAINT TESTED INCONCLUSIVE OR POSTIVE FOR METAL/CERAMIC SUBSTRATE · LEAD-BASED PAINT§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT 0.5MG/CM2 AND IS PRESUMED LEAD PAINT AS SET FORTH IN (28 RCNY §11-07(b)) AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE-USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(b)(2) EAST WALL, WEST WALL IN THE KITCHEN LOCATED AT APT 409, 4th STORY, 7th APARTMENT FROM NORTH AT EAST |
| Class C | Open | 409 | Sep 12, 2025 | LEAD-BASED PAINT HAZARD- POSITIVE · LEAD-BASED PAINT§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM EAST AT SOUTH WALL, 1st WINDOW FRAME FROM WEST AT NORTH WALL, 2nd WINDOW FRAME FROM WEST AT NORTH WALL IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 409, 4th STORY, 7th APARTMENT FROM NORTH AT EAST |
| Class C | Open | 409 | Sep 12, 2025 | LEAD-BASED PAINT HAZARD- POSITIVE · LEAD-BASED PAINT§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FROM SOUTH AT WEST WALL, 1st DOOR FRAME FROM SOUTH AT WEST WALL, SOUTH WALL, WEST WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 409, 4th STORY, 7th APARTMENT FROM NORTH AT EAST |
| Class A | Open | 409 | Sep 12, 2025 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd PRIVATE HALLWAY FROM EAST LOCATED AT APT 409, 4th STORY, 7th APARTMENT FROM NORTH AT EAST |
| Class C | Open | 409 | Sep 12, 2025 | LEAD-BASED PAINT HAZARD- POSITIVE · LEAD-BASED PAINT§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st CLOSET FROM NORTH AT EAST WALL DOOR, 1st CLOSET FROM NORTH AT EAST WALL DOOR FRAME IN THE FOYER LOCATED AT APT 409, 4th STORY, 7th APARTMENT FROM NORTH AT EAST |
| Class C | Open | 409 | Sep 12, 2025 | CORRECT THE LEAD-BASED PAINT TESTED INCONCLUSIVE OR POSTIVE FOR METAL/CERAMIC SUBSTRATE · LEAD-BASED PAINT§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT 0.5MG/CM2 AND IS PRESUMED LEAD PAINT AS SET FORTH IN (28 RCNY §11-07(b)) AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE-USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(b)(2) EAST WALL IN THE 1st PRIVATE HALLWAY FROM EAST LOCATED AT APT 409, 4th STORY, 7th APARTMENT FROM NORTH AT EAST |
| Class A | Open | 409 | Sep 12, 2025 | PAINT METAL · PAINTING§ 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION AT 1st RISER FROM NORTH AT EAST WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 409, 4th STORY, 7th APARTMENT FROM NORTH AT EAST |
| Class A | Open | 409 | Sep 12, 2025 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 409, 4th STORY, 7th APARTMENT FROM NORTH AT EAST |
| Class A | Open | 409 | Sep 12, 2025 | REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 409, 4th STORY, 7th APARTMENT FROM NORTH AT EAST |
| Class B | Open | 409 | Sep 12, 2025 | REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT WEST WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 409, 4th STORY, 7th APARTMENT FROM NORTH AT EAST |