Class AClosed
Jun 3, 2008
REFIT DOORS ETC. · EGRESS
D26-10.01 ADM CODE REFIT DOOR TO BASEMENT AT FRONT NORTH WEST.
Class AClosed
Jun 3, 2008
FILE PLANS OR RESTORE · ALTERATIONS
§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION WOOD DOOR & ASSEMBLY ERECTED AT TOP OF PUBLIC HALL STAIRS TO 2ND STY.
Class AClosed
Jun 3, 2008
FILE PLANS OR RESTORE · ALTERATIONS
§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION FORMER 6 B ROOMS NOW 1B UNIT & 3 CLASS B ROOMS.
Class BClosed
Jun 3, 2008
PROVIDE ENCLOSURE AT · FIRE EGRESS AND PROTECTION
§ 65 M/D LAW PROVIDE UNDER COMPLETED PERMIT, A PROPER ENCLOSURE FOR THE CENTRAL HEATING PLANT, AT BASEMENT.
Class AClosed
Jun 3, 2008
OCCUPANCY SIGN FOR ROOMS · MINIMUM ROOM SIZES AND OCCUPANCY REGULATIONS
D26-33.03 ADM CODE POST A SIGN IN INDIVIDUAL ROOMS SHOWING MAXIMUM LAWFUL OCCUPANCY FOR SLEEPING PURPOSES AT 2 STY ROOMS.
Class BClosed
Jun 3, 2008Apt 3D
NO SMOKE DETECTOR OR SMOKE DECTOR NOT OPERATIONAL · SMOKE DETECTING DEVICES
D26-20.08,20.09 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS 3 STY APT 3D MISSING. , SECTION '' ''
Class BClosed
Jun 3, 2008
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
D26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CLG CELOTEX 3 STY PUB HALL BATHROOM.
Class BClosed
Jun 3, 2008Apt 3D
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
D26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CLGS CELOTEX 3 STY APT 3D BATHROOM & PRIVATE HALL. LOCATED AT APT 3D
Class AClosedRENT IMPAIRING
Jun 3, 2008
PROVIDE A MANAGER · MISCELLANEOUS SERVICES AND FACILITIES
D26-21.09 ADM CODE PROVIDE A MANAGER WHO SHALL BE RESPONSIBLE FOR THE CONDUCT, OPERATION AND MAINTENANCE OF PREMISES AND WHO SHALL LIVE ON PREMISES OR BE REGULARLY PRESENT THEREIN.
Class AClosed
Jun 3, 2008Apt 1A
NO LOCK AND KEY TO APARTMENT · PROTECTIVE DEVICES AND FIRE PROTECTION
D26-20.05 ADM CODE PROVIDE A LOCK AND KEY TO THE ENTRANCE DOOR OF DWELLING UNIT AND, IF A CL A MULTIPLE DWELLING, ALSO 2 STY APT 1A CHAIN DOOR GUARD. LOCATED AT APT 1A
Class CClosed
Jun 3, 2008
PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER
D26-17.10 ADM CODE PROVIDE READY ACCESS TO BUILDING'S HEATING SYSTEM LOCK CELLAR DOOR 1 STY PUB HALL.
Class CClosed
Jun 3, 2008
POST BOILER ROOM ACCESS NOTICE · HEAT AND HOT WATER
D26-17.10 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDING'S HEATING SYSTEM 1 STY PUB HALL.
Class AClosed
Jun 3, 2008
POST REGISTRATION SIGN · ANNUAL PROPERTY REGISTRATION
D26-41.15 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING.
Class AClosed
Jun 3, 2008
MAINTAIN SPRINKLER REPORT · RETIRED
D26-21.07 ADM CODE MAINTAIN ON THE PREMISES A COPY OF THE SPRINKLER TES T FOR THE CURRENT YEAR.
Class BClosed
Jun 3, 2008
PROVIDE HOSE AND PAIL · SPRINKLER SYSTEM
D26-21.07 ADM CODE PROVIDE A PIECE OF GARDEN HOSE 10 FEET IN LENGTH WITH FEMALE COUPLING AND A 10 QUART PAIL ON PREMISES TO TEST SPRINKLER SYSTEM.
Class BClosed
Jun 3, 2008
RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
D26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE PRESENT 15 WATT FLUORESCENT FIXTURE WITH MINIMUM OF 20 WATT FIXTURE OR EQUIVALENT ILLUMINATION 2 STY PUB HALL.
Class BClosed
Jun 3, 2008
INADEQUATE LIGHTING IN YARD OR COURT · ARTIFICIAL LIGHTING
SECTION 27-2040 ADM CODE INSTALL AND MAINTAIN SUFFICIENT LIGHT OR LIGHTS OF AT LEAST 100 WATTS INCANDESCENT OR EQUIVALENT EACH, TO LIGHT ADEQUATELY FROM SUNSET TO SUNRISE THE EAR YARD NIGHT INSPECTION.
Class BClosed
Jun 3, 2008
MAKE DOORS SELF-CLOSING · EGRESS
SECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE 2 STY APT.
Class BClosed
Jun 3, 2008
REPAIR PLASTER · MAINTENANCE
SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING 2 STY APT BATHROOM .
Class BClosed
Jun 3, 2008
ABATE THE NUISANCE · MAINTENANCE
SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCKING DEVICE ON REAR WEST ROOM DOOR TO FIRE ESCAPE WINDOW 2 STY APT.
Class BClosed
Jun 3, 2008
ABATE THE NUISANCE · MAINTENANCE
SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCKING DEVICE ON REAR EAST DOOR 2 STY APT.
Class BClosed
Jun 3, 2008
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERATIVE 2 STY APT TENANT YONG MUN.
Class BClosed
Jun 3, 2008
ABATE THE NUISANCE · MAINTENANCE
SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DOUBLE CYLINDER LOCK VESTIBULE DOOR TO 1 STY PUB HALL .
Class AClosed
Jun 3, 2008
FILE PLANS OR RESTORE · ALTERATIONS
§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION TRANSOM REMOVED & SEALED WITH PLYWOOD ABOVE ENTRANCE DOOR TO 2 STY UNIT 1A.
Class BClosed
Jun 3, 2008
MAKE DOORS SELF-CLOSING · EGRESS
D26-10.01, 10.05 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE 2 STY UNIT 2A.
Class BClosed
Jun 3, 2008
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
D26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CLG 3 STY PUB HALL BATHROOM.
Class AOpen
Jun 3, 2008
PROVIDE RAIN LEADER · SEWERS AND DRAINAGE
SECTION 27-2027 ADMIN. CODE: PROVIDE PROPERLY TRAPPED, SEWER CONNECTED, RAIN LEADER SO AS TO PROVIDE PROPER DRAINAGE AND FILE AN APPLICATION FOR APPROVAL BEFORE DOING THE WORK 1ST TO 2ND STY. ROOFS ALL SIDES.
Class AOpen
Jun 3, 2008
PROVIDE A GUTTER · SEWERS AND DRAINAGE
SECTION 27-2027 ADMIN. CODE: PROVIDE A GUTTER, PROPERLY CONNECTED TO DRAINAGE SYSTEM, FOR PROPER DRAINAGE 1ST & 2ND STY. ROOFS ALL SIDES.
Class AOpen
Jun 3, 2008
PAINT WINDOW FRAMES AND SASHES · PAINTING
SECTION 27-2014 ADMIN. CODE: PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE EXTERIOR WINDOW FRAMES AND SASHES ALL WINDOWS ALL STORIES ALL SIDES.
Class BOpen
Jun 3, 2008
ABATE THE NUISANCE · MAINTENANCE
SECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF DISCUSED, JUNK AND UNREGISTERED AUTOS REAR YARD.
Class BOpen
Jun 3, 2008
SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS BASEMENT WINDOWS ALL SIDES.
SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS BASEMENT WINDOWS ALL SIDES.
Class BOpen
Jun 3, 2008
REPAIR · MAINTENANCE
SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL FIXTURE CEILING FRONT PORCH.
Class BOpen
Jun 3, 2008
FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN · EGRESS
SECTION 27-2005 ADMIN. CODE: FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING 1-2-3 & 4 RUNG UP FIRE LADDER NORTH FIRE ESCAPE.
Class BOpen
Jun 3, 2008
FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN · EGRESS
SECTION 27-2005 ADMIN. CODE: FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING BOTTOM FRONT RAIL 3RD STY. BALCONY NORTH FIRE ESCAPE.
Class BOpen
Jun 3, 2008
REMOVE ACCUMULATION OR RUBBISH · CLEANING
SECTION 27-2010, 2011, 2012 ADMIN. CODE: REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE YARDS ALL SIDES.
Class AOpen
Jun 3, 2008
REPAIR PLASTER · MAINTENANCE
SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR WALL 1ST STY. PUBLIC HALL.
Class BOpen
Jun 3, 2008
REPAIR · MAINTENANCE
SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTICE LOCK ASSEMBLY ENTRANCE DOOR- 2ND STY. APT.
Class BOpen
Jun 3, 2008
REPAIR FLUSHING APPARATUS OF WATER CLOSET · SEWERS AND DRAINAGE
SECTION 27-2026 ADMIN. CODE: REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET 3RD STY. BATHROOM.
Class BOpen
Jun 3, 2008
REMOVE BARS OR GATES FROM FIRE ESCAPE WINDOW · EGRESS
SECTION 27-2005,2007 ADMIN. CODE: FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR GATES FROM WINDOW TO FIRE ESCAPE 3RD STY. NORTH EAST ROOM.
Class COpen
Jun 3, 2008
REMOVE ACCUMULATION OF RUBBISH, WATER & DISINFECT · CLEANING
SECTION 27-2010,2011,2012 ADMIN. CODE: CLEANSE AND DISINFECT TO THE SATISFACTION OF THIS DEPARTMENT AFTER REMOVING THE CELLAR THROUGHOUT- ER-1. - (ACCUMULATION OF WATER AND RUBBISH)
Class BOpen
Jun 3, 2008
REPLACE · MAINTENANCE
SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING ELECTRICAL FIXTURE EAST WALL PRIVATE HALL 3RD STY.
Class BOpen
Jun 3, 2008
REPLACE · MAINTENANCE
SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING GLASS WINDOWS NORTH WEST ROOM AND NORTH WALL NORTH EAST ROOM 3RD STY.
Class AOpen
Jun 3, 2008
NO PEEP HOLE · PROTECTIVE DEVICES AND FIRE PROTECTION
SECTION 27-2041 ADMIN. CODE: PROVIDE A PEEP HOLE IN ENTRANCE DOOR OF THE DWELLING UNIT SO LOCATED AS TO PERMIT A PERSON INSIDE THE DWELLING UNIT TO VIEW ANY PERSON OUTSIDE ENTRANCE DOOR 2ND STY. APT.
Class BOpen
Jun 3, 2008
REMOVE VERMIN · EXTERMINATION & RODENT ERADICATION
SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF VERMIN MICE AND ROACHES ALL ROOMS 3RD STY.
Class BOpen
Jun 3, 2008
ABATE THE NUISANCE · MAINTENANCE
SECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRICAL WIRES EAST WALL SOUTHEAST ROOM 2ND STY. APT.
Class BOpen
Jun 3, 2008
REPAIR LEAKY FAUCETS · WATER SUPPLY
SECTION 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS WASH BASIN BATHROOM 2ND STY. APT.2.
Class BOpen
Jun 3, 2008
SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS UPPER SASH KITCHEN AND LOWER SASH SOUTHWEST ROOM 2ND STY. APT. 2ND STY. APT.
SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS UPPER SASH KITCHEN AND LOWER SASH SOUTHWEST ROOM 2ND STY. APT. 2ND STY. APT.
Class BOpen
Jun 3, 2008
REMOVE VERMIN · EXTERMINATION & RODENT ERADICATION
SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF VERMIN MICE AND ROACHES 2ND STY. APT.
Class AOpen
May 28, 2008
REPAIR · MAINTENANCE
D26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK STILE ENTRANCE DOOR TO 2ND STY FRONT SOUTH UNIT 3.
Class AOpen
May 28, 2008
REPAIR PLASTER · MAINTENANCE
D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING OF REAR ROOM 1ST STY SOUTH UNIT.