Class BOpen
Nov 10, 2025Apt B2
TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ.FT AT SOUTH WALL IN THE BATHROOM LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 18083008 ISSUED 10-JUL-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3)(a) or (b).
Class BOpenRENT IMPAIRING
Nov 6, 2025
REMOVE ENCUMBRANCES · EGRESS
§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF CONSTRUCTION MATERIALS, BICYCLE UNDER STAIR CASE AT PUBLIC HALL, 1st STORY
Class BOpen
Nov 6, 2025
REPLACE · MAINTENANCE
§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING DOOR KNOB AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY
Class BOpen
Nov 6, 2025
PROVIDE SUPPLY OF ELECTRICTY TO FIXTURES · ARTIFICIAL LIGHTING
§ 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES LIGHT FIXTURE AT CEILING AT PUBLIC HALL, 3rd STORY
Class BOpen
Oct 9, 2025Apt B2
TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET EAST WALL IN THE BATHROOM LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 17973833 ISSUED 09-JUN-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3)(a) or (b).
Class BOpen
Sep 30, 2025Apt B2
TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ.FT AT SOUTH WALL IN THE BATHROOM LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 17925237 ISSUED 29-MAY-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3)(a) or (b).
Class BOpen
Sep 11, 2025
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCHAND ASSEMBLY AT BUILDING ENTRANCE DOOR (STREET TO VESTIBULE) AT PUBLIC HALL, 1st STORY
Class BOpenRENT IMPAIRING
Sep 5, 2025
REMOVE ENCUMBRANCES · EGRESS
§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF BICYCLE CHAINED TO BALUSTERS UNDER PUBLIC HALL STAIRS LEADING TO SOUTH YARD , 1st STORY
Class BOpen
Sep 5, 2025Apt B5
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AT STEAM RISER IN THE 4th ROOM FROM EAST LOCATED AT APT B5, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BOpen
Sep 5, 2025
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT BASEMENT
Class BOpen
Sep 5, 2025
PROVIDE SUPPLY OF ELECTRICTY TO FIXTURES · ARTIFICIAL LIGHTING
§ 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING AT PUBLIC HALL, 1st STORY
Class BOpen
Sep 5, 2025Apt B5
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT STEAM RISER IN THE 4th ROOM FROM EAST LOCATED AT APT B5, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BOpenRENT IMPAIRING
Sep 5, 2025
REMOVE ENCUMBRANCES · EGRESS
§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF CONSTRUCTION MATERIALS UNDER PUBLIC HALL STAIRS LEADING TO SOUTH YARD , 1st STORY
Class BOpen
Sep 5, 2025
PROVIDE · MAINTENANCE
§ 27-2005 ADM CODE PROVIDE OPERABLE KNOB AT DOOR AT BULKHEAD ALLOWING RE-ENTRY FROM ROOF TO BULKHEAD
Class BOpen
Sep 5, 2025Apt B5
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AT STEAM RISER IN THE 2nd ROOM FROM EAST LOCATED AT APT B5, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BOpen
Sep 5, 2025
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT BASEMENT
Class BOpen
Sep 5, 2025Apt B5
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT STEAM RISER IN THE 2nd ROOM FROM EAST LOCATED AT APT B5, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BOpen
Sep 3, 2025Apt B2
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL AND RETURN SYSTEM FROM APARTMENT TO BUILDING FRONT IN THE FOYER LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen
Sep 3, 2025
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INOPERATIVE BELL, RETURN BUZZER SYSTEM FROM VESTIBULE AT 1ST STORY PUBLIC HALL TO THE ENTIRE APARTMENT D4 AT PUBLIC HALL, 1st STORY
Class BOpen
Aug 27, 2025Apt B2
TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING. LESS THEN 10 SQ.FT. IN THE BATHROOM LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 17855739 ISSUED 28-APR-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3)(a) or (b).
Class BOpen
Aug 12, 2025Apt B2
TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ.FT AT CEILING AND SOUTH WALL IN THE BATHROOM LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 17822237 ISSUED 12-APR-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
Class BOpenRENT IMPAIRING
Jul 11, 2025Apt B2
REPAIR FLUSHING APPARATUS OF WATER CLOSET · SEWERS AND DRAINAGE
§ 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET IN THE BATHROOM LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen
Jul 11, 2025Apt B2
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen
Jul 11, 2025Apt B2
REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen
Jul 9, 2025Apt B2
REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen
Jul 9, 2025Apt B2
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen
Jul 9, 2025Apt B2
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING, SOUTH WEST AND EAST WALL IN THE BATHROOM LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen
Jun 27, 2025Apt C1
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE AT SOUTH WALL IN THE BATHROOM LOCATED AT APT C1, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH
Class BOpen
Jun 27, 2025Apt C1
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT C1, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH
Class BOpen
Jun 27, 2025Apt C1
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT C1, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH
Class BOpen
Jun 11, 2025Apt B2
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK OVER CEILING IN THE BATHROOM LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen
Jun 11, 2025Apt B2
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen
Jun 11, 2025Apt B2
REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen
Jun 11, 2025Apt B2
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT EAST WALL IN THE BATHROOM LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen
Jun 11, 2025Apt B2
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS IN THE BATHROOM LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpenRENT IMPAIRING
Jun 2, 2025
REMOVE ENCUMBRANCES · EGRESS
§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF CONSTRUCTION MATERIALS AT PUBLIC HALL, 1st STORY
Class BOpen
Jun 2, 2025Apt B2
REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen
Jun 2, 2025Apt B2
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen
Jun 2, 2025Apt B2
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING WEST WALL IN THE PRIVATE HALLWAY LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpenRENT IMPAIRING
May 21, 2025
REMOVE ENCUMBRANCES · EGRESS
§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS. CONSTRUCTION MATERIALS, BICYCLE AT PUBLIC HALL, 1st STORY
Class BOpen
May 21, 2025Apt B2
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK ON CEILING, NORTH, SOUTH AND EAST WALLS IN THE BATHROOM LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen
May 21, 2025Apt B2
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING AND WEST WALL IN THE KITCHEN LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen
May 21, 2025Apt B2
REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen
May 21, 2025Apt B2
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen
May 19, 2025
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MISSING LATCH AT DOOR TO SOUTH YARD AT PUBLIC HALL, 1st STORY
Class BOpen
May 19, 2025Apt B2
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpenRENT IMPAIRING
May 19, 2025Apt B2
REPAIR FLUSHING APPARATUS OF WATER CLOSET · SEWERS AND DRAINAGE
§ 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET IN THE BATHROOM LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen
May 19, 2025Apt B2
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen
May 19, 2025Apt B2
REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen
May 19, 2025Apt B2
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT SOUTH WALL IN THE BATHROOM LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST