stoop
Map
LeaderboardAbout
Building SafetyHousing Conditions

41-41 51 STREET

Queens · ZIP 11377 · BIN 4030733 · Sunnyside · Last violation Jan 12, 2026 · Last complaint May 29, 2026

NeighborhoodSunnyside
More violations than 82.2% of nearby buildings
More violations than 82% of buildings and more complaints than 95% of buildings in Sunnyside. Size-normalized against residential buildings in the neighborhood for issues in the last 10 years.
ViolationsComplaints
Activity TrendsLast 5 years
A steady level of activity over time
Last 2 yrs: 89 violations · 314 complaints
'21'26ViolationsComplaints
▼ View all activity over time
Severityⓘopen violations
16 immediately hazardous (Class C) violations still open
Class C violations include lead paint, mold, pest infestations, heat/hot water failure, and structural hazards — the most serious category.
Class Cimmediately hazardous16Class Bhazardous50
Housing Preservation & Development Violations
Total violations since 1989
388
10 per year avg.→ Stable in the last 2 years
Open violations
79
Class C (immed. haz.)ⓘ16
Class B (hazardous)ⓘ50
Rent-impairingⓘ5
Open violation ages
▪ 3–12 months16% (13)
▪ 1–3 years48% (38)
▪ 3+ years35% (28)
Housing Preservation & Development Complaints
Total complaints since 2003
1,964
82 per year avg.↑ Up 69% in the last 2 years (314 vs 186 prior 2 yrs)
Complaint Resolution
No access20%Violation issued12%No violation18%Phone resolved49%Other1%(1,964)
Urgency breakdown
Last 12 mo.

Top violation categories

5 yrsAll time
Maintenanceⓘ77 violations
Egressⓘ63 violations
Extermination & Rodent Eradicationⓘ16 violations
Cleaningⓘ13 violations
Water Supplyⓘ12 violations
Carbon Monoxide Detecting Devicesⓘ7 violations
Paintingⓘ6 violations
Smoke Detecting Devicesⓘ5 violations
Top complaint groupsⓘ
5 yrsAll time
Heat / hot waterⓘ244 complaints
Bldg maintenanceⓘ127 complaints
Water & plumbingⓘ69 complaints
Mold & pestsⓘ39 complaints
Appliancesⓘ22 complaints
Elevatorⓘ18 complaints
Safety & fireⓘ4 complaints
Electricalⓘ3 complaints
Adminⓘ1 complaints
Hide violations ↑See complaints →

Violation log

388 violations

All classesClass AClass BClass CClass IAllOpenClosed
ClassStatusApt

Building safety complaints, construction, permits, and structural issues filed with the NYC Dept. of Buildings, are scored separately.

Building Safety →
See something wrong? File a complaint with 311
Prior 4 yr.
Immed. Emergency2%2%
Emergency41%70%
Non-Emergency57%28%
(129)
(446)
Issued
Description
Class BOpen6NMar 14, 2007REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS & CEILING IN THE BATHROOM LOCATED AT APT 6N, 6th STORY, APARTMENT AT NORTH
Class BOpenRENT IMPAIRING6NMar 14, 2007LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE BATHROOM LOCATED AT APT 6N, 6th STORY, APARTMENT AT NORTH
Class BClosed6NMar 14, 2007REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS & CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 6N, 6th STORY, APARTMENT AT NORTH
Class BClosedRENT IMPAIRING6NMar 14, 2007LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 6N, 6th STORY, APARTMENT AT NORTH
Class BOpen6NJan 23, 2007REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS & CEILING IN THE BATHROOM LOCATED AT APT 6N, 6th STORY, APARTMENT AT WEST
Class BClosedRENT IMPAIRING6NJan 23, 2007LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 6N, 6th STORY, APARTMENT AT WEST
Class AOpen6NJan 23, 2007PAINT METAL · PAINTING§ 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION HEAT RISER IN THE BATHROOM LOCATED AT APT 6N, 6th STORY, APARTMENT AT WEST
Class BClosed6NJan 23, 2007REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT EAST & WEST WALLS IN THE BATHROOM LOCATED AT APT 6N, 6th STORY, APARTMENT AT WEST
Class BOpen6NJan 23, 2007MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE --- IN THE ENTRANCE LOCATED AT APT 6N, 6th STORY, APARTMENT AT WEST
Class AClosed6NJan 23, 2007NO LOCK AND KEY TO APARTMENT · PROTECTIVE DEVICES AND FIRE PROTECTION§ 27-2043 ADM CODE PROVIDE A LOCK AND KEY TO THE ENTRANCE DOOR OF DWELLING UNIT AND, IF A CL A MULTIPLE DWELLING, ALSO CHAIN DOOR GUARD AT DOOR IN THE ENTRANCE LOCATED AT APT 6N, 6th STORY, APARTMENT AT WEST
Class BClosed6NJan 23, 2007REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS & CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 6N, 6th STORY, APARTMENT AT WEST
Class BClosed2PDec 7, 2006REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2P, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
Class BClosed2PNov 2, 2006NO SMOKE DETECTOR OR SMOKE DECTOR NOT OPERATIONAL · SMOKE DETECTING DEVICES§ 27-2045, 2046 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2P, 2nd STORY
Class AClosed6SJun 12, 2006PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT , 1st WALL CABINET FROM NORTH AT EAST WALL IN THE KITCHEN LOCATED AT APT 6S, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class AClosed6SJun 12, 2006PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT , WEST WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 6S, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class AClosed6SJun 12, 2006PAINT METAL · PAINTING§ 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION , 1st RADIATOR FROM SOUTH AT WEST WALL, 1st RADIATOR FROM EAST AT SOUTH WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 6S, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed6SJun 12, 2006REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE PRIVATE HALLWAY LOCATED AT APT 6S, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class AClosed6SJun 12, 2006PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT , CEILING, NORTH WALL, EAST WALL IN THE BATHROOM LOCATED AT APT 6S, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class AClosed6SJun 12, 2006PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT , NORTH WALL, CEILING, SOUTH WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 6S, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class AClosed6SJun 12, 2006PAINT METAL · PAINTING§ 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION , 1st DOOR FROM NORTH AT EAST WALL, 1st DOOR FRAME FROM NORTH AT EAST WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 6S, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class CClosed7GJun 8, 2005LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING, EAST WALL IN THE FOYER LOCATED AT APT 7G, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''-'', AT WEST
Class CClosed7GJun 8, 2005LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING, SOUTH WALL IN THE BATHROOM LOCATED AT APT 7G, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''-'', AT WEST
Class CClosed7GJun 8, 2005LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 7G, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''-'', AT WEST
Class CClosed7GJun 8, 2005LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING, SOUTH WALL, WEST WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 7G, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''-'', AT WEST
Class CClosed6PMay 26, 2005LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING IN THE BATHROOM LOCATED AT APT 6P, 5th STORY, 3rd APARTMENT FROM WEST AT NORTH
Class BClosed6UJan 21, 2005REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR ,MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6U, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT EAST
Class BOpen6JNov 22, 2004NO CO DETECTOR OR DETECTOR NOT OPERATIONAL · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 6J, 6th STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed6DJul 28, 2004MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ENTRANCE TO 5 STY APT 6D. LOCATED AT APT 6D
Class BClosed4TJul 28, 2004REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE 3 STY APT 4T TENANT DOE. LOCATED AT APT 4T
Class BOpen6JJul 28, 2004REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE 5 STY APT 6J TENANT SANTANA. LOCATED AT APT 6J
Class BClosed—Jul 28, 2004WRENCH AND 3 SPRINKLER HEADS NOT PROVIDED · SPRINKLER SYSTEM§ 27-2050 ADM CODE PROVIDE 3 EXTRA SPRINKLER HEADS AND SUITABLE WRENCH FOR EMERGENCY PURPOSES AT O.S.Y. VALVE OF SPRINKLER IN ACCORDANCE WITH THE RULES AND REGULATIONS OF THIS DEPARTMENT MISSING AT COMPACTOR ROOM CELLAR EAST
Class CClosed5KJul 28, 2004ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF LOCKED DOOR TO ROOM WITH FIRE ESCAPE WINDOW OBSTRUCTING EGRESS 4 STY APT 5K ER1. LOCATED AT APT 5K
Class BClosed6CJul 28, 2004MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ENTRANCE DOOR TO 6 STY APT 6C. , SECTION '' ''
Class BClosed—Jul 28, 2004WRENCH AND 3 SPRINKLER HEADS NOT PROVIDED · SPRINKLER SYSTEM§ 27-2050 ADM CODE PROVIDE 3 EXTRA SPRINKLER HEADS AND SUITABLE WRENCH FOR EMERGENCY PURPOSES AT O.S.Y. VALVE OF SPRINKLER IN ACCORDANCE WITH THE RULES AND REGULATIONS OF THIS DEPARTMENT MISSING AT COMPACTOR ROOM CELLAR WEST
Class BClosed5RJul 28, 2004REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICESD26-20.08 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE 5 STY APT 5R TENANT JENTER SOUTH REAR SECTION. , SECTION '' ''
Class BOpen4PJul 28, 2004REMOVE BARS OR GATES FROM FIRE ESCAPE WINDOW · EGRESSD26-10.01, 10.05 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE 4 STY APT 4P SOUTH REAR SECTION. LOCATED AT APT 4P
Class AOpen7GJul 28, 2004NO LOCK AND KEY TO APARTMENT · PROTECTIVE DEVICES AND FIRE PROTECTION§ 27-2043 ADM CODE PROVIDE A LOCK AND KEY TO THE ENTRANCE DOOR OF DWELLING UNIT AND, IF A CL A MULTIPLE DWELLING, ALSO CHAIN DOOR GUARD 6 STY APT 7G FRONT SECTION. LOCATED AT APT 7G
Class CClosed7FJun 20, 1989REPEALED: LEAD - BASED PAINT · RETIRED§ 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT NORTH WALL & CEILING SOUTHWEST ROOM & NORTH ROOM CEILING 6 STY APT 7F YONEDA 335 6454 ER1. , SECTION '' ''
Page 8 of 8
← Prev