stoop
Map
LeaderboardAbout
Building SafetyHousing Conditions

100 BELMONT PLACE

Staten Island · ZIP 10301 · BIN 5112989 · St. George-New Brighton · Last violation Apr 15, 2026 · Last complaint Apr 10, 2026

NeighborhoodSt. George-New Brighton
More violations than 92.8% of nearby buildings
More violations than 93% of buildings and more complaints than 96% of buildings in St. George-New Brighton. Size-normalized against residential buildings in the neighborhood for issues in the last 10 years.
ViolationsComplaints
Activity TrendsLast 5 years
A steady level of activity over time
Last 2 yrs: 172 violations · 192 complaints
'21'26ViolationsComplaints
▼ View all activity over time
Severityⓘopen violations
15 immediately hazardous (Class C) violations still open
Class C violations include lead paint, mold, pest infestations, heat/hot water failure, and structural hazards — the most serious category.
Class Cimmediately hazardous15Class Bhazardous36
Housing Preservation & Development Violations
Total violations since 2000
1,445
54 per year avg.↑ Up 17% in the last 2 years (172 vs 147 prior 2 yrs)
Open violations
62
Class C (immed. haz.)ⓘ15
Class B (hazardous)ⓘ36
Rent-impairingⓘ0
Open violation ages
▪ 30–90 days2% (1)
▪ 3–12 months66% (41)
▪ 1–3 years31% (19)
▪ 3+ years2% (1)
Housing Preservation & Development Complaints
Total complaints since 2003
1,864
78 per year avg.↓ Down 36% in the last 2 years (192 vs 299 prior 2 yrs)
Complaint Resolution
No access12%Violation issued28%No violation33%Phone resolved26%Other0%(1,864)
Urgency breakdown
Last 12 mo.

Top violation categories

5 yrsAll time
Maintenanceⓘ137 violations
Extermination & Rodent Eradicationⓘ46 violations
Egressⓘ43 violations
Cleaningⓘ35 violations
Paintingⓘ27 violations
Water Supplyⓘ27 violations
Heat And Hot Waterⓘ17 violations
Smoke Detecting Devicesⓘ12 violations
Top complaint groupsⓘ
5 yrsAll time
Heat / hot waterⓘ277 complaints
Mold & pestsⓘ102 complaints
Bldg maintenanceⓘ78 complaints
Water & plumbingⓘ65 complaints
Appliancesⓘ19 complaints
Electricalⓘ11 complaints
Safety & fireⓘ7 complaints
Hide violations ↑See complaints →

Violation log

880 violations · Class B

All classesClass AClass BClass CClass IAllOpenClosed
ClassStatusApt

Building safety complaints, construction, permits, and structural issues filed with the NYC Dept. of Buildings, are scored separately.

Building Safety →
See something wrong? File a complaint with 311
Prior 4 yr.
Immed. Emergency1%2%
Emergency60%68%
Non-Emergency39%30%
(83)
(535)
Issued
Description
Class BClosed4FMar 20, 2015REPAIR LEAKY FAUCETS · WATER SUPPLY§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 3rd APARTMENT FROM NORTH AT EAST
Class BClosed4FMar 20, 2015REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTERBALANCE AT LOWER SASH EAST NORTH WINDOW IN THE 1st ROOM FROM NORTH LOCATED AT APT 4F, 4th STORY, 3rd APARTMENT FROM NORTH AT EAST
Class BClosed4FMar 20, 2015REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). '' MISSING '' IN THE ENTIRE APARTMENT LOCATED AT APT 4F, 4th STORY, 4th APARTMENT FROM NORTH AT EAST
Class BClosed—Mar 20, 2015REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF FLOWER POTS AT FRONT CENTER BALCONY AT FIRE ESCAPE, 6th STORY
Class BClosed—Mar 20, 2015REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCKING-DEVICE AT ENTRANCE DOOR AT VESTIBULE AT PUBLIC HALL, 1st STORY
Class BClosed4FMar 20, 2015REPAIR LEAKY FAUCETS · WATER SUPPLY§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASHBASIN IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 3rd APARTMENT FROM NORTH AT EAST
Class BClosed4FMar 20, 2015REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INOPERATIVE VENTILATING SYSTEM IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 3rd APARTMENT FROM NORTH AT EAST
Class BClosed4FMar 20, 2015ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATION§ 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4F, 4th STORY, 3rd APARTMENT FROM NORTH AT EAST
Class BClosed5CJan 29, 2015ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATION§ 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed5CJan 29, 2015REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed5CJan 29, 2015REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed5JDec 23, 2014REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BOTTOM SASH SOUTH WINDOW IN THE 2nd ROOM FROM EAST LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed5JDec 23, 2014REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MECHANICAL AIR VENT IN THE BATHROOM LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed5JDec 23, 2014REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BOTTOM SASH WINDOW IN THE 1st ROOM FROM EAST LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed5JDec 9, 2014REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND WALLS IN THE BATHROOM LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed5JDec 9, 2014TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... PRESENT AT CEILING ( APPROX-4 SQ,FT ) IN THE BATHROOM LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed5JDec 9, 2014REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed5JDec 9, 2014REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR '' DEFECTIVE '' IN THE ENTIRE APARTMENT LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed5JDec 9, 2014REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). '' MISSING '' IN THE ENTIRE APARTMENT LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed5JDec 9, 2014REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND BATHTUB IN THE BATHROOM LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed2DSep 11, 2014REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed2DSep 11, 2014REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT WEST WALL IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed2DSep 11, 2014REPLACE · MAINTENANCE§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING CERAMIC TILES AT SOUTH WALL IN THE 2nd BATHROOM LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed—Aug 4, 2014RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WIRE GLASS AT FIRE PROOF DOOR TO FIRE STAIR AT PUBLIC HALL, 5th STORY, SECTION ''A'', AT SOUTH
Class BClosed2FJan 17, 2014REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERABLE LOCATED AT APT 2F, 2nd STORY, 4th APARTMENT FROM WEST AT NORTH
Class BClosed—Jul 8, 2013REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIRCONDITIONER PROTRUDING BEYOND WINDOW SILL AT FRONT CENTER BALCONY AT FIRE ESCAPE AT EAST , 1st STORY
Class BClosed—Jul 8, 2013REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF FLOWER POTS AT BALCONY AT FIRE ESCAPE AT NORTH , 2nd STORY
Class BClosed—Jul 8, 2013REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF FLOWER POTS AT BALCONY AT FIRE ESCAPE AT NORTH , 5th STORY
Class BClosed2JJul 8, 2013REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). '' MISSING '' IN THE ENTIRE APARTMENT LOCATED AT APT 2J, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed2JJul 8, 2013REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2J, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed2JJul 8, 2013REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 2J, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed2JJul 8, 2013TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... PRESENT AT CEILING ( APPROX- 3 SQ,FT ) IN THE BATHROOM LOCATED AT APT 2J, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed1GJun 6, 2013REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILING IN THE 1st BATHROOM FROM EAST LOCATED AT APT 1G, 1st STORY, 4th APARTMENT FROM NORTH AT EAST
Class BClosed2HJun 6, 2013MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .. IN THE ENTRANCE LOCATED AT APT 2H, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed1GJun 6, 2013TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... PRESENT AT CEILING ( APPROX- 8 SQ,FT ) AND LOWER SOUTH WALL ( APPROX- 12 SQ,FT ) IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 1G, 1st STORY, 4th APARTMENT FROM NORTH AT EAST
Class BClosed1GJun 6, 2013TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... PRESENT AT LOWER EAST AND NORTH WALLS ( APPROX-4 SQ,FT ) INSIDE-CLOSET IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 1G, 1st STORY
Class BClosed1GJun 6, 2013REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 1G, 1st STORY, 4th APARTMENT FROM NORTH AT EAST
Class BClosed1GJun 6, 2013REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND SOUTH WALL IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 1G, 1st STORY, 4th APARTMENT FROM NORTH AT EAST
Class BClosed1GJun 6, 2013REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st BATHROOM FROM EAST LOCATED AT APT 1G, 1st STORY, 4th APARTMENT FROM NORTH AT EAST
Class BClosed1GJun 6, 2013TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... PRESENT AT CEILING OVER SHOWER-STALL ( APPROX- 12 SQ,FT ) IN THE 1st BATHROOM FROM EAST LOCATED AT APT 1G, 1st STORY, 4th APARTMENT FROM NORTH AT EAST
Class BClosed1GJun 6, 2013TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... PRESENT AT LOWER NORTH WALL ( APPROX- 4 SQ.FT ) IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 1G, 1st STORY, 4th APARTMENT FROM NORTH AT EAST
Class BClosed1GJun 6, 2013REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR LOWER NORTH WALL IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 1G, 1st STORY, 4th APARTMENT FROM NORTH AT EAST
Class BClosed1GJun 6, 2013REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT NORTH WALL AT SHOWER-STALL IN THE 1st BATHROOM FROM EAST LOCATED AT APT 1G, 1st STORY, 4th APARTMENT FROM NORTH AT EAST
Class BClosed2JMay 28, 2013REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK OVER CEILING IN THE BATHROOM LOCATED AT APT 2J, 2nd STORY
Class BClosed2JMay 28, 2013REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 2J, 2nd STORY
Class BClosed2JMay 28, 2013NO CO DETECTOR OR DETECTOR NOT OPERATIONAL · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2J, 2nd STORY
Class BClosed1GMay 28, 2013TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... 2 SQUARE FEET AT EAST CLOSEST EAST WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 1G, 1st STORY
Class BClosed1GMay 28, 2013REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT NORTH WALL IN THE 3rd BATHROOM FROM NORTH LOCATED AT APT 1G, 1st STORY
Class BClosed1GMay 28, 2013REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING AND SOUTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1G, 1st STORY
Class BClosed1GMay 28, 2013REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND SOUTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1G, 1st STORY